7CP476.60-1

System 2003 CPU
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

B&R 7CP476.60-1 is system 2003 cpu. It executes System 2003 control applications and provides isolated CAN plus serial communication and four screw-in expansion positions.

Ask our team:

Get a quick price for: 7CP476.60-1
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 7CP476.60-1

Technical specifications for 7CP476.60-1

  • Manufacturer:
    B&R
  • Product Category:
    PLC Systems
  • Spare Part Number:
    7CP476.60-1
  • Estimated shipping dimensions:
    15.3x11.2x6cm
  • Weight:
    0.52 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • SRAM:
    750 kB
  • FlashPROM:
    1.5 MB
  • Supply:
    24 V DC
  • Power consumption:
    12.5 W
  • Interfaces:
    RS232; CAN
  • CAN:
    Electrically isolated; network-capable
  • Expansion:
    4 screw-in module slots

Information

Information

Overview Manuals Common Applications Product Precautions
B&R 7CP476.60-1 is system 2003 cpu. It executes System 2003 control applications and provides isolated CAN plus serial communication and four screw-in expansion positions.
  • Provides 750 kB SRAM
  • Provides 1.5 MB FlashPROM
  • Integrates isolated network-capable CAN
  • Accepts four screw-in interface modules

7CP476.60-1 operates with System 2003 rack and I/O, 24 V DC supply, approved screw-in modules, Automation Studio application backup.

Engineered applications include System 2003 machine controller, CAN device integration, Serial equipment control, Legacy CPU replacement.

Important Notice: Back up application and retained data, identify all screw-in modules, record CAN node settings and verify I/O before production restart.

Apter Power B&R 7CP476.60-1 Manuals and Guides

Apter Power B&R 7CP476.60-1 Product and System Technical Reference PDFApter Power B&R 7CP476.60-1 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

System 2003 machine controller

Runs installed machine logic.

CAN device integration

Coordinates CAN-connected equipment.

Serial equipment control

Maintains serial device communication.

Legacy CPU replacement

Restores a legacy controller from the approved program.

Read the applicable B&R instructions before work. Verify 7CP476.60-1 and the installed B&R System 2003 PLC configuration.
1

Verify the full 7CP476.60-1 marking and its assigned B&R System 2003 PLC position before work.

2

Place the connected machine or process in the approved maintenance state.

3

Isolate the applicable supply and plc execution plus rs232, can and system 2003 i/o data field energy before disconnecting conductors.

4

Record connector, conductor, address and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed System 2003 rack and I/O and 24 V DC supply against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended system 2003 machine controller function and retain the final test result.

Technical notes

Technical notes

Back up application and retained data, identify all screw-in modules, record CAN node settings and verify I/O before production restart.

FAQS

  • Which installed system position is intended for 7CP476.60-1?
    Install 7CP476.60-1 only in the documented B&R System 2003 PLC position and verify the complete catalog marking against the approved hardware list.
  • What signal or controlled function does 7CP476.60-1 handle?
    Its documented duty is plc execution plus rs232, can and system 2003 i/o data; the official record lists flashprom as 1.5 MB.
  • Which companion hardware must be matched to 7CP476.60-1?
    Match 7CP476.60-1 with System 2003 rack and I/O and 24 V DC supply, including the documented carrier, cable and project identity.
  • Which electrical value must be verified before wiring 7CP476.60-1?
    Verify power consumption: 12.5 W. Do not transfer limits from another catalog number.
  • How should the configuration be preserved when replacing 7CP476.60-1?
    Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R System 2003 PLC configuration.
  • Which isolation and handling checks apply to 7CP476.60-1?
    Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling 7CP476.60-1.
  • How should an engineer commission 7CP476.60-1?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended system 2003 machine controller function.
  • Can 7CP476.60-1 replace a visually similar module without further checks?
    No automatic substitution is assumed; compare the full catalog number, interfaces, sram and approved system revision.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.