The 2711-T10C8 functions as an AC-powered operator terminal within the Allen-Bradley PanelView 1000 product line. The hardware features a 10.4-inch analog-resistive touchscreen that displays full-color graphics. For power supply integration, the terminal operates within an input voltage range of 85 to 264 Volts AC, matching a frequency block of 47 to 63 Hertz.
Data Highway Plus (DH+) industrial network communication port
Equipped with an independent 1008 KB nonvolatile flash memory
The colored touch screen provides a touch actuation lifespan of approximately 1 million presses
In terms of data storage and capacity allocation, this component includes 1008 Kbytes of built-in nonvolatile flash memory and is separately equipped with 310 Kbytes of application runtime memory. In addition to these two basic built-in storage options, the 2711-T10C8 features an external expansion slot that supports the use of ATA flash memory cards to provide additional external data storage volume for the factory floor. Besides acting as an excellent command input module, the device accomplishes its core external data interaction through the combination of its built-in Data Highway Plus (DH+) network communication port and a dedicated RS232 printer interface.
The integrated DH+ port is responsible for exchanging real-time data with on-site PLC5, SLC500, and other Allen-Bradley programmable logic controllers, and it also supports linking with any third-party hardware devices that are compatible with the DH+ protocol. This communication mode utilizes a three-wire shielded cable for physical connection, which easily accommodates long-distance wiring layouts and enables cluster communication between a single terminal and multiple controllers. Operating as an auxiliary channel, the RS232 interface is primarily utilized to connect alarm printers, enabling immediate printouts of on-site system alarms and vital events for historical archives and routine inspection reports.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Allen-Bradley 2711-T10C8 PanelView 1000 Touch Manuals, Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Automotive Manufacturing
Mounted on control cabinets within stamping shops or body welding lines to display robotic arm sequence steps, mold clamping statuses, and weld counts.
Pharmaceuticals & Biotechnology
Integrated into material weighing and capsule filling machinery to monitor batch formulation ratios, cleanroom differential pressures, and environmental temperature/humidity alarm logs.
Petrochemical & Refining
Placed on local control boxes of long-distance pipeline booster stations or centrifugal separation skids to provide on-site visual monitoring of pipeline pressure, compressor speed, and safety shutdown valve status.
Power Generation
Serves as a local operator terminal in power plant auxiliary control systems (e.g., boiler makeup water, ash handling systems) for screen navigation and manual/automatic valve open-close controls.
Mining & Mineral Processing
Positioned on the exterior of explosion-proof electrical cabinets in coal washing plants or ore crushing units to display belt conveyor overload alarms and silo material level heights.
Pulp & Paper
Integrated into the wire, press, or reeler consoles of paper machines, enabling operators to alter dryer cylinder steam pressure parameters and monitor paper thickness and basis weight indicators.
When using the 2711-T10C8 touch terminal, a minimum safety clearance of 51 mm (2 inches) must be strictly maintained on all sides to ensure air convection, and its Data Highway Plus (DH+) 3-wire network wiring requires proper terminating resistor matching, meaning direct cross-plugging with standard Ethernet cables is strictly forbidden.
Additionally, field replacement of removable components like the clock battery or backlight assembly must be executed under total power-down conditions to avoid short-circuiting the circuit boards, and projects inside the 1008 KB flash memory should be backed up regularly using an external ATA flash memory card completely offline, while the use of chemically corrosive solvents to wipe down the 1-million-press touch panel is strictly prohibited.
The 2711-T10C8 is an Allen-Bradley PanelView Standard 1000 graphic color touch terminal featuring a 640 x 480 pixel 10.4-inch display and 1008 Kbytes internal flash memory, equipped with a built-in DH+ network port and an RS232 printer interface to facilitate long-distance, multi-node communication with PLC5 or SLC500 controllers via a 3-wire cable alongside automated alarm logging. Configured exclusively for horizontal flush-mounting, it requires a 51 mm (2-inch) cooling and working clearance on all sides within an indoor enclosure rated NEMA 12/13/4X and IP54/IP65, and it must operate within environment thresholds of 0 to 55 °C, 15 g shock, and 2 g vibration (up to 2,000 Hz) supported by proper thermal and vibration mitigation devices to secure maximum operational lifespan.
What specific type of industrial automation hardware is the 2711-T10C8?
It is a PanelView 1000 series industrial touch-screen Human-Machine Interface (HMI) terminal manufactured by Allen-Bradley, utilized for the visual presentation of machine operating data and operator inputs.
What is the primary use of the 2711-T10C8 on the factory floor?
It is secured onto control cabinet panels to exchange variables with Programmable Logic Controllers (PLCs) via digital circuits, enabling operators to directly monitor and control the status of shop-floor machinery.
What physical operator input mechanism does the 2711-T10C8 utilize?
It receives mechanical press inputs via an integrated analog resistive touch screen using a finger or a dedicated stylus; it does not support physical keypad buttons.
What types of industrial communication interfaces are built into the 2711-T10C8?
It includes a native DH+ (Data Highway Plus) communication port for connecting to early PLC processors and an RS-232 serial port for printer or computer connections.
How are the screen logic and variable tags programmed and developed for the 2711-T10C8?
The text, buttons, and data link libraries must be configured on an external computer using Rockwell's dedicated PanelBuilder32 software, and the compiled project file is subsequently downloaded into the terminal.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.