Honeywell FC-TSRO-0824
Honeywell FC-TSRO-0824
Honeywell FC-TSRO-0824
Honeywell FC-TSRO-0824
Honeywell FC-TSRO-0824
Honeywell FC-TSRO-0824
Product image is representative; revision or series may vary. Contact us to request a specific version.

FC-TSRO-0824

Relay Output FTA
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Provides eight fused relay channels for documented Safety Manager output duties. Verify the nominal 24 V DC drive and field-load ratings against the installed design.

Ask our team:

Get a quick price for: FC-TSRO-0824
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FC-TSRO-0824

Technical specifications for FC-TSRO-0824

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    FC-TSRO-0824
  • Estimated shipping dimensions:
    30x7x6.2cm
  • Weight:
    0.5 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Output channels:
    8
  • Nominal coil voltage:
    24 Vdc
  • Maximum coil voltage:
    36 Vdc
  • Pickup voltage:
    19.2 Vdc
  • Typical coil current:
    40 mA
  • Contact rating:
    5 A fused
  • Switching voltage:
    250 Vac/Vdc maximum
  • Switching load:
    1250 VA; 150 W
  • Safety integrity:
    SIL 3
  • Module type:
    Relay output Field Termination Assembly
  • Safety class:
    Up to and including SIL3
  • Nominal input voltage:
    24 V DC
  • Maximum input voltage:
    36 V DC
  • Relay pick-up voltage:
    19.2 V DC
  • Input current:
    Typically 40 mA at 24 V DC
  • Maximum output current:
    5 A fused
  • Minimum output current:
    1 mA at 5 V
  • Maximum output voltage:
    250 V AC / 250 V DC
  • Maximum switched load:
    1250 VA / 150 W
  • Fuse rating:
    5 A; Schurter 0001.2511

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell FC-TSRO-0824 is an eight-channel relay-output Field Termination Assembly for Safety Manager. It accepts a nominal 24 V DC input and provides fused relay contacts for controlled field loads.
  • Eight independently wired relay output channels
  • 24 V DC relay-drive input
  • Fused 5 A output paths
  • Safety Manager FTA architecture up to SIL3

Record the FC-TSRO-0824 terminal assignments, fuse condition and relay-load ratings before replacement. Verify the 24 V DC drive circuit and prove each output channel under the approved safety-test procedure.

Important Notice: Verify FC-TSRO-0824 from the physical marking and current manufacturer documentation before installation or configuration.

Apter Power Honeywell FC-TSRO-0824 Manuals and Guides
Apter Power Honeywell FC-TSRO-0824 Product Technical ReferenceApter Power Honeywell FC-TSRO-0824 Installation and Verification Guide

Important Notice: Use these model-specific records together with the current manufacturer publication and the installed-system documentation.

Safety shutdown outputs
Switches documented final elements through eight fused relay channels.
Fire and gas actions
Provides relay isolation for configured alarm and trip duties.
Burner management outputs
Drives approved interlocks or permissive loads within published contact ratings.
Legacy Safety Manager maintenance
Restores the recorded TSRO-0824 termination and fuse arrangement.
Read the applicable Honeywell instructions before work. Verify FC-TSRO-0824 and the installed system configuration.
1
Verify the complete FC-TSRO-0824 marking and hardware revision before work.
2
Place affected safety functions in the approved maintenance state.
3
Confirm the nominal 24 V DC input and do not exceed 36 V DC.
4
Record all eight channel terminal assignments before disconnecting conductors.
5
Use only the documented 5 A fuse type and observe the ambient derating curve.
6
Verify each AC or DC field load remains within the published voltage and switched-load limits.
7
Prove relay pick-up, contact state and feedback channel by channel.
8
Restore the approved cause-and-effect test before service release.

Technical notes

Technical notes

Record the FC-TSRO-0824 terminal assignments, fuse condition and relay-load ratings before replacement. Verify the 24 V DC drive circuit and prove each output channel under the approved safety-test procedure.

FAQS

  • How many relay output channels are provided by FC-TSRO-0824?
    Eight relay output channels are documented.
  • What nominal input supply is specified for FC-TSRO-0824?
    The nominal input is 24 V DC.
  • At what voltage does the relay pick up in FC-TSRO-0824?
    The published relay pick-up voltage is 19.2 V DC.
  • What is the maximum fused output current for FC-TSRO-0824?
    The published maximum is 5 A per documented fused output path.
  • Which fuse part is specified for FC-TSRO-0824?
    Honeywell lists a 5 A Schurter fuse, manufacturer part 0001.2511.
  • What output voltage limit applies to FC-TSRO-0824?
    The maximum is 250 V AC or 250 V DC.
  • What safety class is documented for FC-TSRO-0824?
    The FTA is documented for use up to and including SIL3.
  • What must be tested after replacing FC-TSRO-0824?
    Test all eight relay channels, feedbacks, fuse states and the approved safety cause-and-effect sequence.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.