FC-SAO-022M

Safe Analog Output
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Honeywell FC-SAO-022M is the FC-SAO-022M Safe Analog Output Module used for safe generation and monitoring of two analog current-output channels in a documented Honeywell Safety Manager installation. Confirm the complete identity and installed system configuration before replacement.

Ask our team:

Get a quick price for: FC-SAO-022M
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FC-SAO-022M

Technical specifications for FC-SAO-022M

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    FC-SAO-022M
  • Estimated shipping dimensions:
    2x18.9x12.8cm
  • Weight:
    0.16 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Safe analog output module
  • Channels:
    2
  • Output range:
    0(4)-20 mA
  • Allowed load:
    Resistive or capacitive
  • D/A conversion:
    12-bit per output channel
  • Output verification:
    A/D readback per channel
  • Secondary de-energizing:
    Provided for each channel
  • Execution:
    Conformally coated FC version
  • Redundant analog output:
    Supported by the documented Safety Manager release

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell FC-SAO-022M is the FC-SAO-022M Safe Analog Output Module used for safe generation and monitoring of two analog current-output channels in a documented Honeywell Safety Manager installation. Confirm the complete identity and installed system configuration before replacement.
  • Product type: Safe analog output module
  • Model: FC-SAO-022M
  • Channels: 2
  • Output range: 0(4)-20 mA

Use FC-SAO-022M in its documented Honeywell installation with the specified interfaces and configuration. Verify the installed function during controlled commissioning.

Important Notice: Confirm the exact FC-SAO-022M identity, host, wiring, configuration and acceptance results before release.

FC-SAO-022M Manuals & Downloads

These documents are different: the first covers product and system data; the second covers installation checks, commissioning steps and acceptance guidance.

FC-SAO-022M Safe analog output module
Honeywell FC-SAO-022M is the FC-SAO-022M Safe Analog Output Module used for safe generation and monitoring of two analog current-output channels in a documented Honeywell Safety Manager installation.
Installed-system maintenance
Preserves the documented slot, wiring and configuration during replacement.
Controlled commissioning
Restores power and signals in the approved sequence and checks diagnostics.
Acceptance verification
Confirms the intended function before release.
Read the applicable Honeywell installation instructions before work. Verify FC-SAO-022M, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete FC-SAO-022M identity on the hardware and maintenance record.
2
Place the affected process in the approved maintenance state.
3
Record the installed position, connectors, terminals, wiring and configuration before removal.
4
Isolate all documented power and field energy and apply ESD controls where required.
5
Inspect the replacement identity, revision, interfaces and mating hardware before installation.
6
Restore every conductor, cable, power path and configuration value to the approved record.
7
Review host, module, channel or network diagnostics after controlled energization.
8
Perform a controlled test of two safe analog current-output channels before release.

Alternative Names

Alternative Names

FC-SAO-022M

Technical notes

Technical notes

Install FC-SAO-022M only in its documented Honeywell Safety Manager position. Preserve the exact interfaces, wiring and configuration, then verify diagnostics and safe generation and monitoring of two analog current-output channels under controlled conditions.

FAQS

  • How many current outputs are provided by FC-SAO-022M?
    The module provides two safe analog output channels.
  • Which ranges can FC-SAO-022M deliver?
    Each channel supports 0-20 mA or 4-20 mA operation.
  • What load types may be connected to FC-SAO-022M?
    Use resistive or capacitive loads; inductive loads are not permitted.
  • How does FC-SAO-022M check the commanded current?
    An A/D converter reads back each channel's output value.
  • Which converter resolution is used by FC-SAO-022M?
    Each output channel uses a 12-bit D/A converter.
  • Can FC-SAO-022M force an output to de-energize independently of the application value?
    Yes. Each channel has a secondary de-energizing path.
  • What does the FC prefix identify on FC-SAO-022M?
    It identifies the conformally coated Safety Manager execution.
  • What functional test is required for FC-SAO-022M?
    Apply controlled current commands, confirm readback and de-energizing behavior, and review diagnostics on both channels.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.