CC-PAON01 51410070-175

CC-PAON01 High-Level Analog Output Module
In Stock
Ships by Friday, October 2
Fast Shipping Available

Product Describe:

Honeywell CC-PAON01 51410070-175 is a 16-channel Series C high-level analog output module for 4-20 mA process signals.

Ask our team:

Get a quick price for: CC-PAON01 51410070-175
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for CC-PAON01 51410070-175

Technical specifications for CC-PAON01 51410070-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51410070-175
  • Estimated shipping dimensions:
    14.5x5.5x14.5cm
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    High-level analog output module
  • Module model:
    CC-PAON01
  • I/O family:
    Experion PKS Series C I/O
  • Channels:
    16 analog outputs
  • Output range:
    4-20 mA
  • Direct-set range:
    0 mA or 2.9-21.1 mA
  • Maximum load:
    800 ohm with 22-28 V supply
  • Compliance voltage:
    16 V
  • Maximum open-circuit voltage:
    22 V
  • Response:
    Within 1% in 80 ms
  • Calibrated accuracy:
    +/-0.35% of full scale at 25 degC
  • Linearity:
    +/-0.05% of full scale nominal
  • Resolution:
    +/-0.05% of full scale
  • Drift:
    0.005% of full scale per degC
  • Output ripple:
    Less than 100 mV peak-to-peak across 250 ohm at line frequency
  • Readback accuracy:
    +/-4% of full scale
  • Redundancy:
    Optional
  • Diagnostics:
    Output readback discrepancy and open-wire detection
  • Nonincendive field wiring:
    Supported by documented execution
  • Non-redundant IOTA:
    CC-TAON01
  • Redundant IOTA:
    CC-TAON11

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell CC-PAON01 51410070-175 provides generation and supervision of sixteen 4-20 mA process outputs in a documented Experion PKS Series C I/O installation.
  • Sixteen 4-20 mA outputs
  • Output readback and discrepancy monitoring
  • Open-wire diagnostics
  • Optional redundant Series C arrangement

The component remains matched to its documented host position, field connections and approved engineering configuration. Commissioning restores that architecture and verifies the intended function under controlled conditions.

Important Notice: Confirm CC-PAON01 51410070-175, its exact host, installed position, interfaces, configuration, diagnostics and controlled acceptance evidence before release.

CC-PAON01 51410070-175 Manuals & Downloads

These documents are different: the first consolidates verified product and system data; the second provides model-specific installation checks, commissioning steps and acceptance guidance.

Process valve positioning
Drives documented 4-20 mA final-control elements from a Series C output channel.
Analog setpoint delivery
Provides supervised current outputs for compatible process devices.
Redundant analog output
Uses the approved redundant IOTA and peer-module arrangement.
Series C replacement
Restores channel assignments, fail behavior and controlled output verification.
Read the applicable Honeywell installation instructions before work. Verify CC-PAON01 51410070-175, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm CC-PAON01 and item number 51410070-175 on the module record.
2
Place all sixteen output loops in the approved maintenance state.
3
Record channel assignments, commanded values, FAILOPT behavior and redundancy status.
4
Isolate the module and field circuits using the documented Series C procedure.
5
Verify the CC-TAON01 or CC-TAON11 IOTA and loop polarity.
6
Restore each 4-20 mA range, load and channel configuration.
7
Review readback discrepancy, open-wire and module diagnostics.
8
Command controlled outputs on every assigned channel before release.

Alternative Names

Alternative Names

CC-PAON01; 51410070-175

Technical notes

Technical notes

Install CC-PAON01 51410070-175 only in the documented Experion PKS Series C I/O position and preserve its exact wiring, interfaces and configuration. After controlled energization, verify diagnostics and generation and supervision of sixteen 4-20 mA process outputs before release.

FAQS

  • How many 4-20 mA channels does CC-PAON01 51410070-175 provide?
    It provides sixteen high-level analog output channels.
  • Which Series C IOTA choices are documented for CC-PAON01 51410070-175?
    CC-TAON01 is the non-redundant IOTA and CC-TAON11 is the redundant IOTA.
  • What maximum load applies to CC-PAON01 51410070-175 with a 22-28 V supply?
    The documented maximum load is 800 ohm.
  • Which output-response figure is documented for CC-PAON01 51410070-175?
    The output reaches within 1% of the commanded value in 80 ms.
  • How does CC-PAON01 51410070-175 detect an output-path problem?
    It supports output readback discrepancy alarming and open-wire detection.
  • Which direct-set current range can be commanded on CC-PAON01 51410070-175?
    The documented direct-set range is 0 mA or 2.9-21.1 mA.
  • When is redundant operation available for CC-PAON01 51410070-175?
    Use the documented redundant IOTA and matched peer-module arrangement.
  • Which controlled test releases CC-PAON01 51410070-175 after replacement?
    Command and measure every assigned output while checking readback and diagnostics.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.