Emerson 5X00119G01
Emerson 5X00119G01
Emerson 5X00119G01
Emerson 5X00119G01
Emerson 5X00119G01
Emerson 5X00119G01
Product image is representative; revision or series may vary. Contact us to request a specific version.

5X00119G01

RTD Input
In Stock
Ships by Friday, October 23
Fast Shipping Available

Product Describe:

Westinghouse 5X00119G01 serves as a rtd input electronics module in the Ovation I/O subsystem. It interfaces resistance-temperature detector input with 5X00121G01 RTD personality module.

Ask our team:

Get a quick price for: 5X00119G01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 5X00119G01

Technical specifications for 5X00119G01

  • Manufacturer:
    Emerson
  • Product Category:
    DCS System
  • Spare Part Number:
    5X00119G01
  • Estimated shipping dimensions:
    12x5.2x16.6cm
  • Weight:
    0.35 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Channels:
    8 RTD inputs
  • Wiring modes:
    3-wire or 4-wire, channel configurable
  • Resolution:
    12 bits
  • Sampling:
    16.67/s at 50 Hz or 20/s at 60 Hz under normal operation
  • Required personality module:
    5X00121G01 only

Information

Information

Overview Manuals Common Applications Product Precautions
Westinghouse 5X00119G01 converts eight resistance-temperature detector inputs to digital data for the Ovation controller using the dedicated 5X00121G01 field interface.
  • Provides eight RTD channels for the documented rtd input electronics module function.
  • Handles resistance-temperature detector input through the specified Ovation I/O subsystem.
  • Works with 5X00121G01 RTD personality module.
  • On-demand self-calibration and channel error reporting support controlled commissioning and diagnostics.

The rtd input electronics module belongs in the controlled Ovation I/O subsystem and works with 5X00121G01 RTD personality module. Its field connection, companion hardware and project configuration must be reviewed together before the channel is returned to service.

Important Notice: Use 5X00119G01 only with 5X00121G01 RTD personality module; verify the field interface and controlled configuration before energizing the subsystem.

Westinghouse 5X00119G01 Manuals & Downloads
Westinghouse 5X00119G01 Official Technical Reference Excerpt (PDF)Westinghouse 5X00119G01 Installation & Commissioning Guide (PDF)

The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

Installed-base maintenance
Restores the documented rtd input electronics module position without changing the approved system architecture.
Loop or channel service
Supports verification of resistance-temperature detector input at the assigned control-system channel.
Planned replacement
Provides an exact-identity replacement path when 5X00121G01 RTD personality module and the field interface have been confirmed.
Commissioning support
Allows the responsible engineer to prove wiring, configuration, status and response for eight RTD channels.
Before installing Westinghouse 5X00119G01, confirm the documented system, interfaces and controlled configuration.
1
Match the complete 5X00119G01 marking to the work order and installed position before removal.
2
Confirm 5X00121G01 RTD personality module before making or breaking any field connection.
3
Keep the assigned resistance-temperature detector input within the documented subsystem and range.
4
Record terminal designations, polarity, common and shield treatment before disconnecting conductors.
5
Inspect module seating, connector keying, terminal condition and strain relief before power is restored.
6
Restore the controlled channel configuration, range selection and alarm or timeout behavior after installation.
7
Check local indicators and controller diagnostics for internal, communication or channel faults during commissioning.
8
Prove the intended response across eight RTD channels and record the acceptance result before release.

Technical notes

Technical notes

Use 5X00119G01 only with 5X00121G01 RTD personality module; verify the field interface and controlled configuration before energizing the subsystem.

FAQS

  • How many RTD channels are digitized by Westinghouse 5X00119G01?
    The electronics module converts eight resistance-temperature detector inputs.
  • Can Westinghouse 5X00119G01 use both three-wire and four-wire sensors?
    Yes. Each channel can be configured independently for a three-wire or four-wire RTD connection.
  • What conversion resolution applies to Westinghouse 5X00119G01?
    The RTD measurements are converted with 12-bit resolution.
  • How does mains frequency affect Westinghouse 5X00119G01 sampling?
    Normal sampling is 16.67 measurements per second at 50 Hz or 20 measurements per second at 60 Hz.
  • Which personality module is mandatory for Westinghouse 5X00119G01?
    The RTD electronics module is documented for use only with 5X00121G01.
  • What maintenance feature supports accuracy on Westinghouse 5X00119G01?
    On-demand self-calibration allows the electronics to refresh its internal measurement reference under controlled conditions.
  • How are wiring errors identified on Westinghouse 5X00119G01?
    Channel error reporting should be reviewed together with the configured three-wire or four-wire selection and the actual sensor lead arrangement.
  • What is a complete commissioning test for Westinghouse 5X00119G01?
    Apply a known resistance to each channel, verify the selected wiring mode, run the prescribed self-calibration and compare all eight converted values.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.