9200-09-01-06-04

Two-wire Seismoprobe velocity transducer
In Stock
Ships by Wednesday, October 7
Fast Shipping Available

Product Describe:

Bently Nevada 9200-09-01-06-04 is the documented two-wire seismoprobe velocity transducer for the 9200 product family. The Bently Nevada 9200 Seismoprobe is a two-wire moving-coil transducer that produces an output proportional to absolute casing velocity without an external power supply.

Ask our team:

Get a quick price for: 9200-09-01-06-04
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 9200-09-01-06-04

Technical specifications for 9200-09-01-06-04

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    9200-09-01-06-04
  • Estimated shipping dimensions:
    10.3x4x4cm
  • Weight:
    0.45 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Orientation / minimum frequency:
    A09: 0 +/-180 degrees; 15 Hz minimum
  • Cable option:
    B01: top mount; no integral cable
  • Mounting stud:
    C06: isolated circular 1/4-20 UNC stud
  • Approval option:
    D04: ATEX/IECEx; isolated base required
  • Transducer principle:
    Two-wire moving coil; no external power
  • Sensitivity:
    20 mV per mm/s (500 mV per in/s), +/-5%
  • Recommended load:
    10 kOhm
  • Temperature coefficient:
    0.2% per degree C
  • Coil resistance:
    1.25 kOhm nominal
  • Coil inductance:
    125 mH nominal
  • Dynamic range:
    2.54 mm peak-to-peak
  • Velocity range:
    25 mm/s
  • Amplitude linearity:
    +/-5% from 0.254 to 127 mm/s at 100 Hz
  • Maximum cable length:
    1,000 ft
  • Operating temperature:
    -29 to +121 degrees C
  • Humidity:
    95%; 100% with the documented cable option

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 9200-09-01-06-04 is the documented two-wire seismoprobe velocity transducer for the 9200 product family.
  • Measures absolute casing vibration velocity with a self-generating moving-coil element.
  • Provides 20 mV per mm/s sensitivity into a 10 kOhm load.
  • Supports long field cable runs up to the documented 1,000 ft limit.
  • Uses model-code options to define orientation, cable, mounting stud and approval.

Install 9200-09-01-06-04 with its ordered orientation, cable option, mounting stud and compatible monitoring input. Commissioning covers rigid mounting, polarity, cable routing, velocity response and baseline acceptance.

Important Notice: Confirm the complete 9200-09-01-06-04 identity, installed interfaces, approved configuration and final functional acceptance record before service release.

Bently Nevada 9200-09-01-06-04 Manuals & Downloads
Bently Nevada 9200-09-01-06-04 Technical Reference (PDF)Bently Nevada 9200-09-01-06-04 Installation & Commissioning Guide (PDF)

Important Notice: The first document presents exact-model technical data and engineering questions. The second provides a separate model-specific installation, configuration and acceptance workflow.

Bearing-housing velocity
Measure absolute casing vibration at a rigid machine-housing location.
Fan casing monitoring
Apply the selected low-frequency response and mounting orientation to fan structures.
Pump and compressor casing
Trend velocity through a compatible monitoring input and approved field wiring.
Long-run sensor wiring
Use the two-wire interface within the documented cable-length and load envelope.
Read the applicable Bently Nevada installation instructions before work. Verify 9200-09-01-06-04, its installed system arrangement and configured interfaces before commissioning.
1
Confirm all four ordering-code groups because orientation, cable, stud and approval change the installation.
2
Mount on a rigid, clean surface and preserve the selected orientation range.
3
Use the specified stud and do not force a mismatched thread into the transducer base.
4
Maintain the two-wire polarity and a compatible 10 kOhm monitoring load.
5
Route field cable within the 1,000 ft limit and protect it from strain and noise pickup.
6
Verify the installed low-frequency cutoff is suitable for the machine speed.
7
Compare bias-free self-generated output and broadband vibration with a controlled baseline.
8
Retain mounting, orientation, wiring, measured velocity and acceptance evidence.

Technical notes

Technical notes

Official-source basis: Bently Nevada 9200 and 74712 Seismoprobe Velocity Transducers Datasheet, 141626 Rev. AE. Verify the complete 9200-09-01-06-04 ordering code, installed nameplate, mounting and monitoring-channel requirements before work.

FAQS

  • How does the A09 orientation option affect installation of 9200-09-01-06-04?
    A09 permits 0 +/-180 degrees and specifies a 15 Hz minimum-frequency configuration.
  • Why is an isolated base required for 9200-09-01-06-04?
    The C06/D04 combination uses the isolated circular 1/4-20 UNC stud arrangement associated with the ATEX/IECEx option.
  • Which approval code is part of the exact identity of 9200-09-01-06-04?
    D04 designates the ATEX/IECEx configuration; preserve the ordered nameplate and installation conditions.
  • What connector arrangement is supplied on 9200-09-01-06-04?
    B01 is the top-mount, no-integral-cable option, requiring the correct separate field connector and cable.
  • How is the 20 mV per mm/s output of 9200-09-01-06-04 evaluated?
    Measure absolute casing velocity into a 10 kOhm load and compare the output with the stated +/-5% sensitivity tolerance.
  • Which motion envelope should not be exceeded by 9200-09-01-06-04?
    Keep mechanical travel within the 2.54 mm peak-to-peak dynamic range and the stated velocity range for the measurement.
  • How does temperature influence the signal from 9200-09-01-06-04?
    Account for the published 0.2% per degree C temperature coefficient across the installed operating range.
  • What proves compliant commissioning of 9200-09-01-06-04?
    Document isolated mounting, approval identity, orientation, connector/cable route, input load, sensitivity and baseline velocity response.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.