3500/46M 176449-06

Four-channel hydro machinery monitor
In Stock
Ships by Wednesday, October 7
Fast Shipping Available

Product Describe:

Bently Nevada 3500/46M 176449-06 is the documented four-channel hydro machinery monitor for the 46M product family. Bently Nevada 3500/46M 176449-06 is a Hydro Monitor that accepts proximity, seismic, dynamic-pressure and air-gap sensor inputs for vibration, position, pressure and multimode hydro measurements.

Ask our team:

Get a quick price for: 3500/46M 176449-06
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 3500/46M 176449-06

Technical specifications for 3500/46M 176449-06

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    3500/46M 176449-06
  • Estimated shipping dimensions:
    2.5x25.5x24cm
  • Weight:
    0.82 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Exact article:
    176449-06 / 3500/46M Hydro Monitor
  • Channels:
    1 to 4 sensor signals
  • Accepted sensors:
    Proximity, seismic, dynamic pressure and air gap
  • Power consumption:
    7.7 W typical
  • Prox/Accel input impedance:
    10 kOhm
  • Velomitor input impedance:
    3.5 MOhm
  • Multimode positive input:
    50 kOhm
  • Hydro velocity sensitivity:
    20 mV per mm/s
  • Hydro acceleration sensitivity:
    1.02 or 2.55 mV per m/s2
  • Buffered-output impedance:
    550 Ohm
  • Recorder output:
    4-20 mA; 0-600 Ohm load; 100 ms or less
  • Transducer supply:
    -23 Vdc nominal for Prox/Velom I/O; +23 Vdc nominal for positive-input I/O
  • Hydro radial direct filter:
    0.104 to 500 Hz
  • Hydro radial rotor-speed range:
    25 to 1,500 cpm
  • Multimode alarm sets:
    Up to eight sets per configured multimode channel

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3500/46M 176449-06 is the documented four-channel hydro machinery monitor for the 46M product family.
  • Accepts one to four proximity, air-gap, velocity or acceleration sensor signals.
  • Provides hydro radial vibration, air gap, velocity, acceleration, thrust and dynamic-pressure functions.
  • Supports up to eight alarm parameter sets for configured multimode channels.
  • Switches machine-mode alarm sets through multimode I/O contacts or gateway commands.

Install 3500/46M 176449-06 only with the documented 46M front/rear module, termination hardware, transducers and approved 3500 rack configuration. Commissioning covers identity, signal path, scaling, alarms and controlled response.

Important Notice: Confirm the complete 3500/46M 176449-06 identity, installed interfaces, approved configuration and final functional acceptance record before service release.

Bently Nevada 3500/46M 176449-06 Manuals & Downloads
Bently Nevada 3500/46M 176449-06 Technical Reference (PDF)Bently Nevada 3500/46M 176449-06 Installation & Commissioning Guide (PDF)

Important Notice: The first document presents exact-model technical data and engineering questions. The second provides a separate model-specific installation, configuration and acceptance workflow.

Hydro radial vibration
Combine shaft gap movement and NX amplitude for hydro-unit protection measurements.
Hydro air-gap monitoring
Condition compatible air-gap sensor signals for static and dynamic assessment.
Multimode operation
Select mode-specific alarm sets as operating state changes.
Dynamic pressure and SEW
Monitor configured pressure or stator-end-winding vibration inputs.
Read the applicable Bently Nevada installation instructions before work. Verify 3500/46M 176449-06, its installed system arrangement and configured interfaces before commissioning.
1
Verify 176449-06 and the installed Hydro I/O type before replacement.
2
Confirm firmware and rack software meet the minimum revision for every configured hydro application.
3
Preserve each paired-channel configuration and the selected machine-mode logic.
4
Match every sensor to its documented sensitivity, polarity and power-supply type.
5
For external multimode termination, use the documented recorder ET block and signal cable 129525.
6
Do not mix external termination blocks with internal-termination I/O modules.
7
Prove mode changes and all applicable Alert/Danger sets with controlled conditions.
8
Record active mode, static values, alarms, buffered outputs and final acceptance results.

Technical notes

Technical notes

Verify 176449-06 and the installed Hydro I/O type before replacement. Record active mode, static values, alarms, buffered outputs and final acceptance results.

FAQS

  • Which sensor families can 3500/46M 176449-06 accept for hydro monitoring?
    The Hydro Monitor accepts proximity, seismic, dynamic-pressure and air-gap sensor inputs; the installed I/O and channel type must match the sensor.
  • How many input channels are available to 3500/46M 176449-06?
    The monitor accepts one to four sensor signals and programs the channels in pairs.
  • Why does 3500/46M 176449-06 require a machine-mode verification during commissioning?
    A multimode channel can hold up to eight alarm parameter sets and select the applicable set through I/O contacts or communications commands.
  • What restriction applies to the Hydro Velocity function of 3500/46M 176449-06?
    The datasheet states Hydro Velocity is valuable for warning and diagnosis but is not suitable for automated machinery protection because of its low-frequency, high-amplitude event behavior.
  • Which termination rule is critical for external multimode use with 3500/46M 176449-06?
    Use the documented multimode recorder ET block and cable 129525; external termination blocks cannot be paired with internal-termination I/O modules.
  • What recorder-output envelope should be tested on 3500/46M 176449-06?
    Each channel provides 4-20 mA proportional to full scale with 0-600 Ohm load capability and a 100 ms or faster update.
  • Why must firmware and software revisions be checked for 3500/46M 176449-06?
    Minimum revisions differ by hydro application, so the configured measurement type must be compared with the ordering-considerations matrix.
  • Which evidence should close a multimode acceptance test for 3500/46M 176449-06?
    Record active mode, selected alarm set, static values, buffered and recorder outputs, Alert/Danger response and mode-transition behavior.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.