The 330101-00-20-90-12-05 is a Bently Nevada 3300 XL 8 mm unarmored probe with 3/8-24 UNF threads, no unthreaded section, a 2.0 in case, 9.0 m FluidLoc cable, ClickLoc connector without protector, and the CSA, ATEX, and IECEx option.
- 3300 XL 8 mm 9 m FluidLoc proximity probe
- 3/8-24 UNF
- None
- 0.0 in
Its 9.0 m integral probe lead connects directly to a 9.0 m 3300 XL Proximitor Sensor without an extension cable, providing non-contacting shaft vibration, position, Keyphasor, or speed measurements while FluidLoc construction impedes liquid migration through the cable interior. For dependable measurement, follow the official system-matching, target, mounting, cabling, environmental, and approval instructions.
Important Notice: The 9.0 m probe is a complete electrical-length configuration and must not be lengthened with an extension cable.
Apter Power 330101-00-20-90-12-05 Original Product Manual
Important Notice: This Apter Power original manual summarizes manufacturer-published technical data for the exact ordering code. Verify the physical nameplate and current manufacturer installation documents before use.
Fluid-Film-Bearing MachineryProvides non-contacting shaft vibration and position measurements on rotating machinery equipped with fluid-film bearings.
Radial Shaft VibrationMeasures dynamic shaft motion relative to the fully threaded 2.0 in probe case mounting location.
Static Shaft PositionMeasures the static gap between the probe tip and a conductive shaft or target through the complete transducer system output.
Long FluidLoc Cable RoutesProvides a continuous 9.0 m lead where an intermediate extension-cable joint is undesirable.
Speed MeasurementSupports rotational-speed measurement when system length, target geometry, and monitoring-channel requirements are satisfied.
Machinery ProtectionSupplies a conditioned vibration or position signal to a compatible Bently Nevada monitoring system.
Read and follow Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet 141194 Rev. AM and the applicable installation instructions before use. Verify the complete ordering code from the physical nameplate and match every component to the published system configuration.
1Connect the 9.0 m probe directly to a 9.0 m Proximitor Sensor; do not add an extension cable.
2Route the long unarmored lead with mechanical protection and maintain the 25.4 mm minimum bend radius.
3Use official 3/8-24 UNF mounting and torque instructions for the fully threaded case.
4Set the gap with the complete 9.0 m system and intended target material.
5Verify the 05 approval marking and current hazardous-area installation drawing.