Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

330103-00-08-10-01-00

Proximity Probe
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Bently Nevada 330103-00-08-10-01-00 is an unarmored 3300 XL 8 mm metric proximity probe with an M10 × 1 thread, 0 mm unthreaded section, 80 mm case, 1.0 m standard lead and protected ClickLoc connector. Match the probe and extension cable to the configured 1 m, 5 m or 9 m Proximitor measurement chain before use.

Ask our team:

Get a quick price for: 330103-00-08-10-01-00
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 330103-00-08-10-01-00

Technical specifications for 330103-00-08-10-01-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    330103-00-08-10-01-00
  • Estimated shipping dimensions:
    19x19x2cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Component:
    3300 XL 8 mm metric proximity probe
  • Probe thread:
    M10 × 1
  • Armoring:
    Unarmored case and lead
  • Unthreaded length:
    0 mm (code 00)
  • Overall case length:
    80 mm (metric code 08)
  • Integral lead length:
    1.0 m (code 10)
  • Connector execution:
    ClickLoc with connector protector
  • Cable execution:
    Standard cable (code 01)
  • Agency approval option:
    00 — not required
  • Probe tip material:
    Polyphenylene sulfide (PPS)
  • Probe case material:
    AISI 303 or 304 stainless steel
  • Probe cable:
    75 Ω triaxial, FEP-insulated
  • Probe DC resistance:
    7.59 ± 0.50 Ω for 1.0 m
  • Standard probe temperature:
    −52 to +177 °C operating/storage
  • Seal caution:
    Below −34 °C may shorten pressure-seal life
  • M10 thread engagement:
    15 mm maximum
  • Forward-mount case torque:
    11.2 N·m recommended
  • Matched system length:
    1 m probe-only, or 5 m / 9 m with extension cable
  • Matched-system scale factor:
    7.87 V/mm (200 mV/mil) nominal
  • Matched-system linear range:
    2 mm (80 mils)
  • Radial-vibration gap:
    Approximately 1.27 mm / −9 Vdc
  • Matched-system frequency response:
    0–10 kHz, +0/−3 dB typical

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 330103-00-08-10-01-00 is an unarmored 3300 XL 8 mm metric proximity probe for a matched displacement and vibration measurement chain.
  • Exact order identity: 330103-00-08-10-01-00
  • M10 x 1 metric case with 0 mm unthreaded section and 80 mm overall length
  • 1.0 m standard lead with protected ClickLoc termination
  • Selected 1 m probe-only, or matched 5 m / 9 m transducer system

Keep the installed 8 mm probe, extension cable where required and Proximitor configuration matched. Verify the target gap and monitored response before returning the machine to service.

Important Notice: Code 08 identifies the 80 mm metric case length, not an 8 mm case length; confirm the complete marking and receiving M10 thread.

330103-00-08-10-01-00 Manuals & Downloads
330103-00-08-10-01-00 Technical Reference (PDF)330103-00-08-10-01-00 Installation & Commissioning Guide (PDF)

These documents serve different purposes: the first records the verified probe and matched-system data; the second covers installation checks, commissioning and acceptance.

Radial shaft vibrationUse 330103-00-08-10-01-00 to track dynamic shaft displacement through a correctly gapped 3300 XL 8 mm measurement chain.
Axial shaft positionUse the configured transducer loop for controlled static position measurement and alarms.
Speed and phase referenceApply the probe in a documented Keyphasor or tachometer channel with the appropriate target.
Matched-system integrationPair the 1 m probe alone or with the selected extension cable and Proximitor sensor for the configured system length.
Before work, verify 330103-00-08-10-01-00, the documented 8 mm measurement chain and the installed machine state.
1
Read the applicable 3300 XL 8 mm datasheet and record the complete 330103-00-08-10-01-00 marking before work.
2
Place the machine and monitoring channel in the approved maintenance state before removing the installed probe.
3
Confirm the receiving M10 x 1 thread, 80 mm case clearance and 15 mm maximum engagement.
4
Inspect the unarmored probe tip, 1.0 m standard lead and protected ClickLoc connector for damage.
5
Match the 1 m probe-only loop or the 5 m / 9 m probe-plus-extension loop to its Proximitor setting.
6
Use the approved forward-mount method and 11.2 N m recommended case torque without straining the lead.
7
Review pressure-seal risk if the installation can expose the probe below -34 deg C.
8
Verify the target gap, polarity, channel diagnostics and controlled monitored response before release.

Technical notes

Technical notes

Use only with the documented 3300 XL 8 mm extension cable and Proximitor configuration. Code 08 specifies an 80 mm metric case, not an 8 mm case length.

FAQS

  • Why does the 08 case code in 330103-00-08-10-01-00 mean 80 mm?
    330103 uses the metric case-length code in 10 mm increments. Code 08 therefore specifies an 80 mm overall case, while the 8 mm product family describes the probe tip.
  • What thread and unthreaded section does 330103-00-08-10-01-00 have?
    It uses an M10 × 1 metric case with a 0 mm unthreaded section (code 00). Check the receiving thread and 15 mm maximum engagement.
  • How is the 330103-00-08-10-01-00 lead terminated?
    The 1.0 m standard lead uses option 01: a miniature coaxial ClickLoc connector with a connector protector.
  • Can 330103-00-08-10-01-00 be used in a 1 m probe-only loop?
    Yes, when the installed 3300 XL 8 mm Proximitor is configured for a 1 m probe-only system. A 5 m or 9 m loop instead requires a matched extension cable.
  • What probe DC resistance should be checked for 330103-00-08-10-01-00?
    For a 1.0 m 3300 XL 8 mm probe, the nominal center-to-outer resistance is 7.59 ± 0.50 Ω. Isolate and follow the applicable test method.
  • How should 330103-00-08-10-01-00 be handled below −34 °C?
    The standard probe range extends to −52 °C, but exposure below −34 °C may cause premature pressure-seal failure. Review the process-seal risk before use.
  • What matched-system gap is used with 330103-00-08-10-01-00 for radial vibration?
    The 3300 XL 8 mm system specifies approximately 1.27 mm (50 mils), corresponding to about −9 Vdc, under its stated AISI 4140 target and calibration conditions.
  • Can a 330103-00-08-10-01-00 be mixed with non-XL 3300 components?
    The XL 8 mm components are electrically and physically interchangeable with specified non-XL 3300 5 mm/8 mm components, but mixed-loop performance is limited to the non-XL system specifications.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.