135613-01-01

High Temperature Case Expansion Transducer System

Product Describe:

High Temperature Case 
Expansion Transducer System 
Non-Linearity: Less than 0.25% full-scale
+13.5 to +26 Vdc, +1 to +6 Vdc

Ask our team:

Get a quick price for: 135613-01-01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 135613-01-01

Technical specifications for 135613-01-01

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    135613-01-01
  • Estimated shipping dimensions:
    26.2x11.8x9cm
  • Weight:
    1.74 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input Power:
    +13.5 to +26 Vdc unregulated, 30 mA minimum
  • Voltage:
    +1 to +6 Vdc, all models
  • Output Noise:
    <10 mV
  • Operating Temperature:
    -25 °C to +85 °C
  • Storage Temperature:
    -55 °C to +125 °C
  • Shock:
    250 g for 11 ms
  • Vibration:
    10 g @ 0 to 2 kHz
  • Linear Range Option:
    25.4 mm (1.0 in) with a 127 mm (5.00) rod
  • Spring Option:
    With spring return

Information

Information

Overview Manuals Common Applications Product Precautions
The 135613-01-01 is a DC high-temperature housing expansion sensor assembly manufactured by Bentley Nevada, USA. It belongs to the category of industrial-grade high-precision, high-reliability linear displacement measurement devices and plays a key role in the asset protection systems of large rotating machinery.
    • High-Precision Linear Sensing
    • High-Temperature & Heavy-Duty Reliability
    • Integrated Electronics & DC-Powered Architecture
An important position measurement in Turbine Supervisory Instrumentation (TSI) is case expansion. Case expansion (sometimes referred to as shell expansion) is the thermal growth of the machine case as it expands during machine startup and on-line operations.  The case expansion transducer system is typically mounted on the foundation at the opposite end from where the turbine casing is attached to the foundation and provides information about the growth of the machine case relative to the foundation. Case expansion is a parameter that you should use a dual transducer arrangement to measure.  This arrangement provides information about the position of the sliding feet on the machine case.  A condition that obstructs or jams one foot could distort the case and damage the machine.  The dual case expansion transducer configuration in conjunction with the 3300 or 3500 monitors provides an alarm for this condition.  The high temperature dual case expansion transducer configuration is compatible only with the 3500/45 Position Monitor.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 Bently Nevada 135613-01-01 High Temperature Case Expansion Transducer Assembly (dc) Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Thermal Power
Used for absolute casing thermal expansion displacement monitoring of bearing pedestals on large steam turbines in subcritical, supercritical, and ultra-supercritical coal-fired power generating units.

Hydroelectric Power
Employed in measuring slow mechanical displacement and structural deformation caused by seasonal temperature fluctuations or high-load operations on thrust bearing supports and heavy-duty metal housings of large pumped-storage or hydro-turbine units.

Nuclear Power
Used for casing thermal elongation measurement of high-power saturated steam turbine sets in nuclear power plant conventional islands, providing safety interlocks and casing sliding foot jammed alarms under large temperature differentials in non-core areas.

Air Separation
Employed in monitoring the thermal displacement of high-temperature stage casings on integrally geared multi-stage centrifugal compressor packages in large oxygen and nitrogen plants to ensure no mechanism jamming.

Petrochemical and Refining
Applied in monitoring casing expansion and alignment changes of driving turbines for large rich gas compressors and centrifugal cracked gas compressors in refinery catalytic cracking and hydrocracking units.

 During the operation of the 135613-01-01, strict adherence to the following protocols is mandatory. First, you must perform initial stroke midpoint pre-load adjustments under cold conditions to ensure sufficient spring travel space and prevent internal bottoming or over-range damage. Second, signal cables must run entirely through protective metal conduits and never be routed with high-voltage power cables to eliminate voltage fluctuations caused by heavy electromagnetic interference. Lastly, regularly inspect the measurement rod for any movement obstruction caused by ash or debris, and verify that the conduit fitting is fully sealed to prevent steam or oil mist from penetrating the housing and causing short circuits.

FAQS

  • What is the 135613-01-01 device?
    The 135613-01-01 is a High Temperature DC Case Expansion Transducer Assembly manufactured by Bently Nevada, which functions as a DC-powered Linear Variable Differential Transformer (DC-LVDT) measurement system.
  • What is the primary industrial application of the 135613-01-01?
    It is primarily used to monitor the thermal case expansion displacement of high-temperature rotating machinery like large steam turbines to prevent mechanical rubs caused by uneven thermal growth.
  • What are the measurement accuracy characteristics of the 135613-01-01?
    The assembly features high industrial accuracy with a measurement stability within 0.125% of full scale and a non-linearity error under 0.25% of full scale.
  • How should the 135613-01-01 be mechanically mounted and secured?
    It needs to be secured firmly in a vertical or horizontal orientation onto an externally fixed foundation bracket using the 4 supplied 1/4-20 UNC mounting bolts and washers.
  • What electrical interface is provided for field wiring on the 135613-01-01?
    The housing provides a standard 1/2-inch industrial conduit fitting allowing external shielded signal cables to enter securely to the internal terminal strip.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.