Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

6AU1455-2AD00-0AA0

SIMOTION D455-2 DP/PN Motion Control Unit
In Stock
Ships by Saturday, September 12
Fast Shipping Available

Product Describe:

Siemens 6AU1455-2AD00-0AA0 is a SIMOTION D455-2 DP/PN programmable multi-axis motion control unit for SINAMICS S120. It executes machine logic and coordinated motion tasks while the integrated drive control manages the connected drive axes.

Ask our team:

Get a quick price for: 6AU1455-2AD00-0AA0
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6AU1455-2AD00-0AA0

Technical specifications for 6AU1455-2AD00-0AA0

  • Manufacturer:
    Siemens
  • Product Category:
    General Automation
  • Spare Part Number:
    6AU1455-2AD00-0AA0
  • Estimated shipping dimensions:
    5x27x41.5cm
  • Weight:
    3.6 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Product type:
    SIMOTION D455-2 DP/PN
  • Motion control system:
    Multi-axis
  • Performance class:
    ULTRA-HIGH Performance
  • Maximum motion-control axes:
    128
  • Minimum PROFIBUS cycle:
    1 ms
  • Minimum servo cycle:
    0.25 ms
  • Integrated drive axes:
    6 servo / 6 vector / 12 V/f, alternative modes
  • Supply voltage:
    24 V DC nominal; 20.4-28.8 V
  • Current consumption, typical:
    1900 mA
  • Inrush current, typical:
    5 A
  • Power loss, typical:
    46 W
  • Working RAM:
    388 MB
  • Additional Java RAM:
    20 MB
  • RAM disk:
    90 MB
  • Retentive memory:
    512 KB
  • Persistent user data on CF:
    1.5 GB
  • Digital inputs:
    12
  • Configurable digital I/O:
    16
  • DRIVE-CLiQ interfaces:
    6
  • PROFINET interface:
    1 interface with 3 ports; RT/IRT
  • Industrial Ethernet interfaces:
    2
  • USB interfaces:
    2
  • Option slots:
    1
  • Operating ambient:
    0 to 55 °C
  • Storage ambient:
    -25 to 55 °C
  • Transport ambient:
    -40 to 70 °C
  • Relative humidity, operation:
    5-95 %
  • Air pressure:
    620-1060 hPa
  • Protection rating:
    IP20 / UL open type
  • Digital input isolation:
    Yes; groups of 6
  • Output current per channel, max.:
    500 mA
  • Resistive output frequency, max.:
    4 kHz
  • Output short-circuit protection:
    Yes

Information

Information

Overview Manuals Common Applications Product Precautions
This exact D455-2 DP/PN article combines the ULTRA-HIGH performance tier of SIMOTION D4x5-2 with onboard memory and communications for complex multi-axis machine projects.
  • Coordinates PLC, positioning, synchronous-operation and cam workloads within one project
  • Supports compact drive-based layouts and distributed multi-controller synchronization
  • Integrates with SINAMICS S120 power components and optional CX32-2 expansion
  • Provides time-critical measuring-input and cam-output handling for machine events

Install the unit in a released D4x5-2 mounting position with the required double fan/battery module and cabinet cooling. It pairs with SINAMICS S120 Line and Motor Modules, a compatible CompactFlash card, engineering software and licensed technology packages; onboard digital signals, DRIVE-CLiQ and industrial networks support packaging, printing, converting, textile, plastics/rubber and handling machinery.

Important Notice: Before replacing 6AU1455-2AD00-0AA0, confirm the full D455-2 DP/PN article, SINAMICS S120 or CX32-2 topology, hardware product version, terminal and connector assignments, 24 V wiring, shielding and grounding, CompactFlash kernel, firmware and engineering-project versions, double fan/battery module and licenses. Restore the project only after these checks, then commission with diagnostics and controlled axis tests; product version C or later is required for the documented TM54F or PROFIsafe safety-control use.

Apter Power 6AU1455-2AD00-0AA0 Manuals and Guides

The Apter Power reference organizes exact-article technical data and validation points. The Siemens manual provides the original installation, wiring, commissioning, hardware-version and diagnostic procedures for the D4x5-2 platform, including 6AU1455-2AD00-0AA0.

6AU1455-2AD00-0AA0 coordinated packaging motion
Runs sequenced machine logic and coordinated motion for packaging equipment whose axes must remain synchronized through production cycles.
6AU1455-2AD00-0AA0 printing and converting lines
Supports registration, synchronous operation and cam-based motion in printing and web-converting machines with tightly timed material movement.
6AU1455-2AD00-0AA0 textile and polymer processing
Coordinates machine sections in textile, plastics and rubber equipment where several drive axes and the process sequence share one control project.
6AU1455-2AD00-0AA0 handling and distributed drives
Connects centralized motion tasks with distributed drive stations for material handling systems that require synchronized transport and positioning.
Use the Siemens D4x5-2 installation and commissioning sequence for 6AU1455-2AD00-0AA0. Keep power isolation, cooling, connection topology, software compatibility and controlled functional testing as separate acceptance checks.
1
Isolate the 24 V control supply and the associated SINAMICS power circuit before handling the control unit; use ESD-safe procedures during removal and installation.
2
Confirm the full article number 6AU1455-2AD00-0AA0 and the installed hardware product version before replacement. For the documented TM54F or PROFIsafe safety-control use, Siemens specifies product version C or later for D455-2 DP/PN.
3
Use only the released mounting positions. Horizontal installation requires the double fan/battery module, 80 mm ventilation clearances and a cabinet cooling concept that keeps inlet and ambient temperature within limits.
4
Reconnect the 24 V supply, digital I/O reference potentials, protective grounding and shields to the documented terminals. Preserve the galvanically isolated grouping of the fixed digital inputs.
5
Reproduce the engineered DRIVE-CLiQ, PROFIBUS and PROFINET port assignments before applying power. Keep unused DRIVE-CLiQ ports protected with the approved blanking method.
6
Match the CompactFlash card, SIMOTION kernel, SINAMICS firmware, engineering project and runtime licenses to the installed hardware before downloading or restoring the project.
7
Commission in stages: verify diagnostics and network roles first, then enable the drive system, check axis feedback and directions, and complete controlled functional tests before returning the machine to service.
8
Complete the post-replacement maintenance check by verifying the double fan/battery module, reviewing the diagnostic buffer, and recording the CompactFlash card, firmware, engineering project and runtime-license versions before release.

Alternative Names

Alternative Names

6AU14552AD000AA0 SIMOTION D455-2 DP/PN

Technical notes

Technical notes

Install 6AU1455-2AD00-0AA0 in the approved vertical position or the specifically released horizontal position; the double fan/battery module is required and 80 mm ventilation clearances apply to horizontal mounting. Before commissioning or replacement, verify the CompactFlash card, SIMOTION/SINAMICS software versions, licensed technology packages, DRIVE-CLiQ/PROFIBUS/PROFINET topology, I/O wiring and the restored project, and use product version C or later when the documented Safety Integrated functions are controlled via TM54F or PROFIsafe.

FAQS

  • Which drive system is 6AU1455-2AD00-0AA0 designed to control?
    It is a SIMOTION D455-2 DP/PN drive-based control unit whose integrated drive control is based on SINAMICS S120. The engineered system can connect SINAMICS S120 drive components through DRIVE-CLiQ and can add drive-processing capacity with CX32-2 or other supported SINAMICS control units.
  • What must be matched before loading a project into 6AU1455-2AD00-0AA0?
    Match the control-unit hardware product version, CompactFlash card, SIMOTION kernel, SINAMICS software, engineering project and required runtime licenses. Restore or download the project only after these items and the configured drive topology agree with the installed machine.
  • Can 6AU1455-2AD00-0AA0 be mounted horizontally?
    Yes. The Siemens D4x5-2 commissioning manual explicitly releases horizontal installation for this article. That arrangement requires the double fan/battery module, 80 mm ventilation clearances and compliance with the documented cooling limits.
  • How can the onboard digital signals of 6AU1455-2AD00-0AA0 be used?
    The unit provides fixed digital inputs plus configurable digital inputs/outputs. The configurable channels can serve as inputs, outputs, measuring inputs or cam outputs as assigned in the engineered project; terminal functions and reference potentials must follow the Siemens wiring documentation.
  • How does 6AU1455-2AD00-0AA0 integrate with PROFIBUS and PROFINET networks?
    Its PROFIBUS interfaces support equidistant and isochronous operation and can be configured for master or slave roles. The onboard PROFINET interface supports IO controller/device functions with RT and IRT; the project determines the actual roles, addresses and redundancy settings.
  • What commissioning sequence should be used after replacing 6AU1455-2AD00-0AA0?
    Verify the article and hardware version, mounting, cooling, 24 V supply, grounding, connectors and bus topology. Then fit the correct CompactFlash card, restore the validated project, review diagnostics and network status, enable drives in stages and perform controlled axis and machine tests.
  • What should be checked if 6AU1455-2AD00-0AA0 does not start correctly after replacement?
    Compare control-unit indicators and diagnostic messages with the previous installation, then check the CompactFlash card, firmware and project compatibility, 24 V supply, DRIVE-CLiQ topology, PROFIBUS/PROFINET configuration and the connected I/O. Correct the identified mismatch before enabling motion.
  • What hardware-version rule applies to safety-related use of 6AU1455-2AD00-0AA0?
    For safety functions controlled through TM54F or PROFIBUS/PROFINET with PROFIsafe, the Siemens commissioning manual lists product version C as the minimum for this article. The manual also states that Control Unit operation uses either PROFIsafe or TM54F control, not mixed operation.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.