T8403

Digital Input Module
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

ICS Triplex T8403 is a Trusted TMR 24 VDC digital input module. It acquires 24 VDC discrete field states and presents triplicated input data to a Trusted TMR controller.

Ask our team:

Get a quick price for: T8403
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for T8403

Technical specifications for T8403

  • Manufacturer:
    ICS Triplex
  • Product Category:
    DCS System
  • Spare Part Number:
    T8403
  • Estimated shipping dimensions:
    3x30.3x26.5cm
  • Weight:
    1.18 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Module type:
    Trusted TMR 24 Vdc digital input
  • Input channels:
    40
  • Architecture:
    Triple Modular Redundant
  • Input conversion:
    Sigma-delta measurement per channel per slice
  • Line monitoring:
    Selectable per channel
  • Isolation barrier:
    2500 V impulse withstand
  • Sequence of Events resolution:
    1 ms
  • Online replacement:
    Companion Slot or SmartSlot
  • Safety certification:
    TUV-certified IEC 61508 SIL 3
  • Typical input termination:
    5 kOhm to 0 V reference
  • Operating temperature:
    0 to 60 deg C

Information

Information

Overview Manuals Common Applications Product Precautions
ICS Triplex T8403 is a Trusted TMR 24 Vdc digital input module with 40 triplicated input channels. It measures each field input against configurable thresholds and provides line monitoring, diagnostics and 1 ms Sequence of Events reporting.
  • Forty triplicated 24 Vdc input channels
  • Per-channel open- and short-circuit line monitoring
  • One-millisecond Sequence of Events reporting
  • Online replacement through Companion Slot or SmartSlot

Record the T8403 module revision, chassis slot, field-cable assembly, threshold configuration and line-monitoring settings before replacement. Verify all 40 channel states, field wiring diagnostics and Active/Standby status before returning the Trusted system to service.

Important Notice: Verify T8403 from the physical marking and current manufacturer documentation before installation or configuration.

Apter Power T8403 Manuals and Guides
Apter Power T8403 Product Technical ReferenceApter Power T8403 Installation and Verification Guide

Important Notice: Use these model-specific records together with the current manufacturer publication and the installed-system documentation.

Emergency shutdown inputs
Acquires safety-related 24 Vdc field contacts with TMR processing and diagnostics.
Fire and gas input monitoring
Uses configurable thresholds and optional line monitoring for supervised field circuits.
Sequence-of-events capture
Records configured input state changes with 1 ms resolution.
Online module maintenance
Supports controlled Active/Standby transfer using Companion Slot or SmartSlot arrangements.
Read the applicable ICS Triplex instructions before work. Verify T8403 and the installed system configuration.
1
Verify the exact T8403 catalog number, revision and intended Trusted chassis slot.
2
Record the module type, revision and serial number before installation.
3
Inspect the housing and rear connector; do not install a module with damage or bent pins.
4
Use static-handling controls and never touch exposed connector pins.
5
Confirm the correct field-cable assembly and FTA/VFTA before insertion.
6
Do not force the module if it does not enter the slot with minimum resistance.
7
Restore threshold and line-monitoring configuration for every used channel.
8
Verify all channel LEDs, module status, SOE operation and field-wiring diagnostics before release.

Technical notes

Technical notes

Record the T8403 module revision, chassis slot, field-cable assembly, threshold configuration and line-monitoring settings before replacement. Verify all 40 channel states, field wiring diagnostics and Active/Standby status before returning the Trusted system to service.

FAQS

  • How many inputs does ICS Triplex T8403 provide?
    T8403 provides 40 field input channels.
  • Why is each ICS Triplex T8403 channel described as TMR?
    Each field input is triplicated and processed by three isolated slices so a single slice fault does not determine the reported state.
  • Can ICS Triplex T8403 detect field wiring faults?
    Yes. Selectable per-channel line monitoring can detect open-circuit and short-circuit field cable conditions when the approved line-monitoring components are installed.
  • What Sequence of Events resolution does ICS Triplex T8403 provide?
    The module provides onboard SOE reporting with 1 ms resolution.
  • Can ICS Triplex T8403 be replaced online?
    Yes. The manual supports online replacement with a dedicated Companion Slot or a SmartSlot configuration under the approved procedure.
  • What isolation is documented for ICS Triplex T8403?
    The product description specifies a 2500 V impulse-withstand opto/galvanic isolation barrier.
  • What should be inspected before inserting ICS Triplex T8403?
    Inspect the housing and rear I/O connector for damage or bent pins, confirm the correct module type and field-cable assembly, and use ESD precautions.
  • What proves successful commissioning of ICS Triplex T8403?
    All configured channel states, thresholds, line-monitoring indications, SOE entries and Active/Standby module status must agree with the approved test record.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

You May Also Like

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.