LCM-320

Loop Controller
In Stock
Ships by Thursday, October 22
Fast Shipping Available

Product Describe:

NOTIFIER LCM-320 is a loop control module that adds a signaling line circuit to compatible ONYX Series fire alarm control panels. Each module also supports one LEM-320 loop expander for a second SLC.

Ask our team:

Get a quick price for: LCM-320
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for LCM-320

Technical specifications for LCM-320

  • Manufacturer:
    Honeywell
  • Product Category:
    General Automation
  • Spare Part Number:
    LCM-320
  • Estimated shipping dimensions:
    25.4×12.70×7.62 cm
  • Weight:
    0.41 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Module function:
    Loop control module
  • System family:
    Compatible NOTIFIER ONYX Series FACPs
  • SLC capacity:
    One SLC per LCM-320
  • Expansion:
    One LEM-320 per LCM-320
  • Nominal operating voltage:
    24 V DC
  • Maximum operating voltage:
    27.6 V DC
  • Maximum module current:
    130 mA
  • Maximum single-SLC current:
    400 mA
  • Maximum loop resistance:
    50 ohms
  • 18 AWG Class B length:
    3,225 ft (983 m)
  • 12 AWG Class B length:
    12,500 ft (3,810 m)
  • Operating temperature:
    0 to 49 °C
  • Relative humidity:
    93 ±2% noncondensing at 32 ±2 °C
  • Recommended room range:
    15 to 27 °C

Information

Information

Overview Manuals Common Applications Product Precautions
The LCM-320 provides an addressable signaling line circuit for compatible NOTIFIER ONYX Series control panels and communicates loop-device status to the host system.
  • One SLC per LCM-320
  • Supports one LEM-320 expander
  • 24 V DC nominal operation
  • 50 ohm maximum loop resistance

The LCM-320 operates as a plug-in loop interface with degraded-mode support and a maximum published module current of 130 mA. In NFS-3030 and NFS2-3030 systems, up to five LCM-320 modules and five associated LEM-320 expanders can provide ten SLCs. Field wiring length, conductor size, current and topology must follow the approved fire-alarm design.

Important Notice: Confirm the LCM-320 marking, panel compatibility, SLC topology, conductor size and approved device schedule before installation.

NOTIFIER LCM-320 Manuals & Downloads
NOTIFIER LCM-320 Official Manufacturer Manual (PDF)NOTIFIER LCM-320 Installation & Commissioning Guide (PDF)

The first document reproduces applicable official manufacturer pages unchanged; the second provides a separate evidence-led installation and commissioning workflow.

ONYX Series SLC
Addressable signaling-line-circuit control in a compatible NOTIFIER ONYX fire alarm control panel.
Expanded loop capacity
A documented LEM-320 can add a second SLC to each installed LCM-320.
NFS-3030 systems
Multi-loop architecture using up to five LCM-320 modules and five associated LEM-320 expanders.
Service replacement
Like-for-like restoration where the panel database, loop topology and device schedule are preserved.
Read the applicable NOTIFIER instructions before work. Verify LCM-320 and the installed system configuration before isolation or replacement.
1
Record the complete LCM-320 marking, panel slot and SLC assignment before work.
2
Place the fire alarm system under the approved impairment and safe-work procedure.
3
Back up the panel database and record loop devices, addresses and current loading.
4
Verify conductor size, topology and total loop resistance against the approved design.
5
Remove operating power before installing or removing the plug-in module.
6
Confirm any LEM-320 expansion and interconnection before restoring the panel.
7
Test every affected loop device, fault indication and degraded-mode response.
8
Document acceptance results and restore the fire alarm system to normal service.

Technical notes

Technical notes

The LCM-320 operates as a plug-in loop interface with degraded-mode support and a maximum published module current of 130 mA. In NFS-3030 and NFS2-3030 systems, up to five LCM-320 modules and five associated LEM-320 expanders can provide ten SLCs. Field wiring length, conductor size, current and topology must follow the approved fire-alarm design.

FAQS

  • What does the NOTIFIER LCM-320 control?
    The NOTIFIER LCM-320 controls one addressable signaling line circuit in a compatible ONYX Series fire alarm control panel.
  • Can one LCM-320 support an additional loop?
    One LCM-320 can support one LEM-320 expander, which adds a second signaling line circuit.
  • How many LCM-320 modules can an NFS2-3030 use?
    An NFS2-3030 can use up to five LCM-320 modules together with five associated LEM-320 expanders.
  • Which operating voltage is specified for LCM-320?
    The LCM-320 operates at 24 V DC nominal with a published maximum of 27.6 V DC.
  • What is the maximum current drawn by the loop controller?
    The LCM-320 loop controller draws a maximum of 130 mA, while one SLC has a published maximum current of 400 mA.
  • How much resistance can the LCM-320 loop tolerate?
    The LCM-320 supports a maximum signaling-line-circuit resistance of 50 ohms.
  • What Class B distance is allowed with 12 AWG wire?
    A Class B LCM-320 loop can reach 12,500 ft (3,810 m) when 12 AWG twisted unshielded wire is used under the published conditions.
  • What must be tested after replacing an LCM-320?
    The technician must test every affected loop device, fault indication, expander connection and degraded-mode response after replacing an LCM-320.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.