C7061F2001

UV Flame Detector
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

Honeywell C7061F2001 is the C7061F2001 Dynamic Self-Check UV Flame Detector used for ultraviolet flame supervision in an explosion-proof detector housing in a documented Honeywell flame safeguard installation. Confirm the complete identity and installed system configuration before replacement.

Ask our team:

Get a quick price for: C7061F2001
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for C7061F2001

Technical specifications for C7061F2001

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    C7061F2001
  • Estimated shipping dimensions:
    24x19.5x31cm
  • Weight:
    6.68 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product type:
    Dynamic self-check ultraviolet flame detector
  • Housing:
    Explosion proof
  • Supply:
    120 VAC, 50/60 Hz
  • Mounting connection:
    1 inch NPT
  • Lead length:
    8 ft / 96 in
  • Ambient range:
    -40 to 175 degF
  • Self-check mechanism:
    Mechanical shutter
  • Field service:
    Replaceable UV sensing tube and quartz viewing window

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell C7061F2001 is the C7061F2001 Dynamic Self-Check UV Flame Detector used for ultraviolet flame supervision in an explosion-proof detector housing in a documented Honeywell flame safeguard installation. Confirm the complete identity and installed system configuration before replacement.
  • Product type: Dynamic self-check ultraviolet flame detector
  • Model: C7061F2001
  • Housing: Explosion proof
  • Supply: 120 VAC, 50/60 Hz

Use C7061F2001 in its documented Honeywell installation with the specified interfaces and configuration. Verify the installed function during controlled commissioning.

Important Notice: Confirm the exact C7061F2001 identity, host, wiring, configuration and acceptance results before release.

C7061F2001 Manuals & Downloads

These documents are different: the first covers product and system data; the second covers installation checks, commissioning steps and acceptance guidance.

C7061F2001 Dynamic self-check ultraviolet flame detector
Honeywell C7061F2001 is the C7061F2001 Dynamic Self-Check UV Flame Detector used for ultraviolet flame supervision in an explosion-proof detector housing in a documented Honeywell flame safeguard installation.
Installed-system maintenance
Preserves the documented slot, wiring and configuration during replacement.
Controlled commissioning
Restores power and signals in the approved sequence and checks diagnostics.
Acceptance verification
Confirms the intended function before release.
Read the applicable Honeywell installation instructions before work. Verify C7061F2001, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete C7061F2001 identity on the hardware and maintenance record.
2
Place the affected process in the approved maintenance state.
3
Record the installed position, connectors, terminals, wiring and configuration before removal.
4
Isolate all documented power and field energy and apply ESD controls where required.
5
Inspect the replacement identity, revision, interfaces and mating hardware before installation.
6
Restore every conductor, cable, power path and configuration value to the approved record.
7
Review host, module, channel or network diagnostics after controlled energization.
8
Perform a controlled test of ultraviolet flame supervision and shutdown response before release.

Alternative Names

Alternative Names

C7061F2001

Technical notes

Technical notes

Install C7061F2001 only in its documented Honeywell flame safeguard position. Preserve the exact interfaces, wiring and configuration, then verify diagnostics and ultraviolet flame supervision in an explosion-proof detector housing under controlled conditions.

FAQS

  • What flame spectrum is detected by C7061F2001?
    It senses ultraviolet radiation from the monitored flame.
  • Why does C7061F2001 include a shutter?
    The mechanical shutter interrupts the UV path so the flame-safeguard system can check detector response.
  • Which enclosure execution is C7061F2001?
    It is the explosion-proof C7061F model.
  • What supply is required by C7061F2001?
    The detector uses 120 VAC at 50 or 60 Hz.
  • Which process connection is used by C7061F2001?
    The mounting connection is 1 inch NPT.
  • How long are the integral leads on C7061F2001?
    The lead length is 8 ft, or 96 in.
  • What ambient range applies to C7061F2001?
    The listed range is -40 to 175 degF.
  • What must be checked before returning C7061F2001 to service?
    Verify sighting, mounting, wiring, shutter action, flame signal and safe shutdown response with the burner in a controlled state.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.