Product Describe:

Redundant IO Termination Assembly

G3 harsher environmental protection

100% Live Hot-Swappable

2 x Dedicated Slots

Ask our team:

Get a quick price for: FC-IOTA-R24
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FC-IOTA-R24

Technical specifications for FC-IOTA-R24

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51306505-175
  • Estimated shipping dimensions:
    44.2x12x6.5cm
  • Weight:
    0.56 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Operating temperature:
    -40 .. +70 °C
  • Storage temperature:
    -40 .. +85 °C
  • Relative humidity:
    10..95% (non condensing)
  • Approvals:
    CE; UL, TUV pending
  • Supply voltage:
    24 Vdc -15%..+30%
  • Supply load:
    max. 10 A
  • Reverse polarity protection:
    parallel diode (blows the fuse)
  • Max Backplane Current:
    15.0 A
  • Voltage Limits:
    18 VDC to 30 VDC
  • Mounting Method:
    MCAR-01 Mounting Carrier

Information

Information

Overview Manuals Common Applications Product Precautions
The FC-IOTA-R24 is a 24 VDC Redundant Input/Output Termination Assembly for the Safety Manager SC platform. This heavy-duty baseplate accommodates twin safety I/O modules, enabling seamless hardware fault tolerance and uninterrupted hot-swapping. It functions as the central physical interface to route industrial field wiring directly into the control architecture, maintaining high-density channel isolation required for SIL3 critical safety loops.
    • Fully compatible with RUSIO-3224 Universal Safety I/O modules
    • Certified compliant with SIL3 safety integrity levels
    • Delivers dual-module fault tolerance and high-speed signal routing
The Honeywell FC-IOTA-R24 acts as the structural wiring backbone for industrial risk-management systems, offering twin slots that mount two identical FC-RUSIO-3224 safety modules alongside each other. By maintaining an internal dual-channel electrical path, the unit mirrors incoming process variables to both mounted components at the same time, preventing total signal loss if one device requires replacement or experiences a component failure. Field-level equipment, such as emergency control valves and hazard sensors, links directly to this single terminal board, minimizing the physical footprint inside automation cabinets by consolidating up to twenty-four separate circuit loops onto a single point.

The unit mounts onto MCAR-01 carrier grids using standard anchoring tabs, positioning the terminal screws at an accessible angle for rapid deployment of single-core or multi-stranded wires between 24 and 12 AWG. The unpowered copper-traced base circuit handles constant voltage levels up to 30 VDC, diverting excess current through onboard protection channels to protect the processing hardware from upstream field faults. This terminal infrastructure satisfies international SIL3 evaluation benchmarks, anchoring the low-level processing nodes of factory emergency trips and gas containment loops without requiring intermediate marshalling panels or extra wiring junctions.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 Honeywell FC-IOTA-R24 Redundant IO Termination Assembly Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Offshore Oil Drilling Platforms
Used to handle highly critical wellhead emergency shutdown and blowout prevention control loops.

Coal Gasification & Advanced Coal Chemicals
Handles safety interlocks for oxygen, coal slurry, or raw coal injection systems in coal gasifiers.

Nuclear Power Plant Conventional Island & Balance of Plant
Monitors the state of high-pressure main steam valves on the conventional island, utilizing 1oo2 hardware logic to guarantee steam closure within seconds during anomalies.

Pharmaceutical API High-Pressure Crystallization & Purification
Protects hazardous workshops involving high-pressure solvent recovery and multiphase reactions for process explosion prevention.

ndustrial Air Separation & Rare Gas Purification
Manages fire prevention and liquid nitrogen/oxygen explosion mitigation under oxygen-enriched environments in Air Separation Units (ASUs).

Petroleum Refining
Controlling critical processes in Fluid Catalytic Cracking Units (FCCU) and atmospheric/vacuum distillation units.

 When using the FC-IOTA-R24 termination assembly, you must strictly adhere to its SIL 3 safety standards and avoid hot-swapping under power to prevent electrical arcing. Ensure correct wiring for both redundant channels and perform regular tests on the redundancy switchover function. Finally, implement proper ESD protection, dust-proofing, and moisture-proofing to keep terminal blocks corrosion-free, guaranteeing long-term high availability and fault-tolerant safety in harsh industrial environments.

Alternative Names

Alternative Names

FC IOTA R24 FC-I0TA-R24 FC-1OTA-R24 FC-10TA-R24

Technical notes

Technical notes

The Honeywell FC-IOTA-R24 is a high density industrial grade 24 VDC Redundant Input Output Termination Assembly for the Safety Manager SC platform. Certified to SIL3 international standards, this baseplate serves as the critical physical interface layer to host Honeywell essential FC-RUSIO-3224 Universal Safety IO modules. It provides robust baseline hardware infrastructure for high risk Emergency Shutdown and Fire and Gas critical safety loops.

FAQS

  • What is the Honeywell FC-IOTA-R24?
    It is a redundant Input/Output Termination Assembly (IOTA) used within the Honeywell Experion PKS (C-Series) automation control system.
  • Which system category does FC-IOTA-R24 primarily belong to in industrial automation?
    It belongs completely to the field Input/Output subsystem (I/O Subsystem) within a Distributed Control System (DCS).
  • How does the FC-IOTA-R24 safeguard fault tolerance in plant control loops?
    It integrates dual-channel power distribution and communication routing buses internally, allowing a backup module to take over without disturbance and without interrupting field signals if one docked primary I/O module experiences a hardware failure.
  • How to correctly physically fix the FC-IOTA-R24 in an industrial field?
    The termination assembly needs to be fixed vertically onto the dedicated mounting channel backplane inside the control cabinet using standard screws through its own alignment holes.
  • Can I/O modules be plugged or unplugged online into an operating FC-IOTA-R24?
    Yes, this hardware baseplate fully supports online hot-swapping, allowing maintenance personnel to safely replace one damaged electronic module without power interruption or system shutdown.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.