IC695ALG616

RX3i 16-Channel Analog Current/Voltage Input Module
In Stock
Ships by Wednesday, September 30
Fast Shipping Available

Product Describe:

Emerson IC695ALG616 is a non-isolated differential analog input module with sixteen single-ended or eight differential channels. It supports software-configurable current and voltage measurements in an RX3i Universal Backplane.

Ask our team:

Get a quick price for: IC695ALG616
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for IC695ALG616

Technical specifications for IC695ALG616

  • Manufacturer:
    Emerson
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC695ALG616
  • Estimated shipping dimensions:
    3.4x13.5x13.7cm
  • Weight:
    0.18 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input channels:
    16 single-ended or 8 differential
  • Current ranges:
    0–20 mA, 4–20 mA and ±20 mA
  • Voltage ranges:
    ±10 V, 0–10 V, ±5 V, 0–5 V and 1–5 V
  • Backplane:
    RX3i Universal Backplane
  • Hot swap:
    Supported
  • Configuration:
    Software configurable; no jumpers
  • Calibration:
    Full autocalibration
  • Diagnostics:
    Open-circuit detection, module and point-fault reporting
  • Alarms:
    High, low, high-high, low-low and rate-of-change
  • Compatible terminal blocks:
    IC694TBB032, TBB132, TBS032 or TBS132

Information

Information

Overview Manuals Common Applications Product Precautions
IC695ALG616 provides high-density analog current and voltage signal acquisition for a matched PACSystems RX3i I/O installation.
  • Exact catalog identity IC695ALG616
  • RX3i 16-Channel Analog Current/Voltage Input Module
  • Documented role: high-density analog current and voltage signal acquisition
  • Controlled installation, diagnostics and functional verification

The component remains matched to the documented RX3i slot or carrier, terminal assembly, field power and engineering configuration. Commissioning preserves the installed architecture and verifies controlled response.

Important Notice: Confirm IC695ALG616, the complete RX3i host, hardware revision, slot, terminal block, field power, wiring, grounding, shielding, configuration, diagnostics and controlled acceptance evidence before release.

Emerson IC695ALG616 Manuals & Downloads

These documents are different: the first consolidates verified product and system data; the second provides installation checks, commissioning steps and acceptance records.

PACSystems RX3i planned maintenance
Restores high-density analog current and voltage signal acquisition in the documented control architecture.
RX3i 16-Channel Analog Current/Voltage Input Module replacement
Uses exact IC695ALG616 identity instead of an adjacent I/O or CPU execution.
Control-system refurbishment
Preserves the installed slot, terminal block, point map, power and engineering configuration.
Controlled recommissioning
Confirms diagnostics and the affected signal or control function before automatic operation.
Read the applicable Emerson installation instructions before work. Verify IC695ALG616, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete IC695ALG616 marking, module designation and documented RX3i installation position.
2
Place the controller, machine and connected process in the approved maintenance state.
3
Isolate controller and field power, prove the safe state and apply ESD controls before handling.
4
Record the slot, terminal block, every point assignment, common, shield and connected circuit before removal.
5
Verify the official electrical and configuration values documented for IC695ALG616; do not infer adjacent catalog executions.
6
Restore the approved backplane or carrier, terminal block, field power and engineering configuration.
7
Energize in the manufacturer sequence and review CPU, bus, module and channel diagnostics.
8
Complete a controlled signal, output or controller-response test before service release.

Alternative Names

Alternative Names

GE IC695ALG616 GE Fanuc IC695ALG616

Technical notes

Technical notes

Install IC695ALG616 only in the documented PACSystems RX3i I/O position. Preserve the as-found terminal, point and configuration records; then verify diagnostics and high-density analog current and voltage signal acquisition under controlled conditions.

FAQS

  • How is IC695ALG616 distinguished from adjacent RX3i catalog numbers?
    Match the complete IC695ALG616 marking, the RX3i 16-Channel Analog Current/Voltage Input Module designation and its recorded slot or carrier position.
  • What function is assigned to IC695ALG616 in the documented system?
    The module provides high-density analog current and voltage signal acquisition in the matched PACSystems RX3i I/O installation.
  • What is the official input channels for IC695ALG616?
    Emerson documents input channels as 16 single-ended or 8 differential; verify that value against the installed execution before work.
  • Which current ranges applies to IC695ALG616?
    The official value is 0–20 mA, 4–20 mA and ±20 mA. Preserve the corresponding power, signal or controller configuration.
  • How should the documented voltage ranges be checked on IC695ALG616?
    Confirm voltage ranges is ±10 V, 0–10 V, ±5 V, 0–5 V and 1–5 V and compare the as-found wiring or configuration with the approved record.
  • What evidence is needed for the backplane of IC695ALG616?
    Record the installed condition and verify the official value RX3i Universal Backplane during controlled commissioning.
  • What must be preserved before replacing IC695ALG616?
    Record the slot or carrier, terminal assembly, point assignments, wiring, commons, shields, firmware or configuration state and active diagnostics.
  • How is IC695ALG616 accepted after installation?
    Restore the documented hardware and point map, review module and controller diagnostics, and perform a controlled test of high-density analog current and voltage signal acquisition.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.