Bently Nevada 3500/32M 125720-02
Bently Nevada 3500/32M 125720-02
Bently Nevada 3500/32M 125720-02
Bently Nevada 3500/32M 125720-02
Bently Nevada 3500/32M 125720-02
Bently Nevada 3500/32M 125720-02
Product image is representative; revision or series may vary. Contact us to request a specific version.

3500/32M 125720-02

Four-channel relay module component
In Stock
Ships by Wednesday, October 7
Fast Shipping Available

Product Describe:

The Bently Nevada 3500/32M is a full-height four-channel relay module whose programmable outputs use monitor alarm and status logic for machinery-protection annunciation and interlocking.

Ask our team:

Get a quick price for: 3500/32M 125720-02
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 3500/32M 125720-02

Technical specifications for 3500/32M 125720-02

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    3500/32M 125720-02
  • Estimated shipping dimensions:
    2.5x11.2x24.2cm
  • Weight:
    0.48 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Exact spare role:
    Output module for hazardous-area and functional-safety systems
  • Relay outputs:
    4 independent SPDT outputs
  • Logic:
    Programmable independent voting with AND/OR combinations
  • Logic inputs:
    Alert, Danger, Not-OK and Programmable Logic states
  • Power consumption:
    5.8 W typical
  • Relay construction:
    Epoxy-sealed; 250 Vrms arc suppressor
  • Standard DC rating:
    2 A at 0-30 Vdc; 0.75 A at 48 Vdc; 0.2 A at 125 Vdc
  • Standard AC rating:
    2 A maximum; 250 Vac maximum; 450 VA maximum
  • Safety/hazardous rating:
    30 Vac/Vdc maximum; 2 A maximum
  • Published contact life:
    100,000 cycles at 5 A, 24 Vdc or 240 Vac reference condition
  • Operating temperature:
    -30 to +65 degrees C
  • Storage temperature:
    -40 to +85 degrees C
  • Relative humidity:
    95%, non-condensing
  • Rack space:
    One full-height front slot and one corresponding rear slot

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3500/32M 125720-02 is the documented four-channel relay module component for the 32M product family.
  • Provides four independent SPDT relay outputs in one full-height module.
  • Combines Alert, Danger, Not-OK and Programmable Logic states with AND/OR voting.
  • Uses epoxy-sealed relays with arc suppression for controlled switching.
  • Supports documented standard-system and safety/hazardous-area output limits.

Install 3500/32M 125720-02 only with the documented 32M front/rear module, termination hardware, transducers and approved 3500 rack configuration. Commissioning covers identity, signal path, scaling, alarms and controlled response.

Important Notice: Confirm the complete 3500/32M 125720-02 identity, installed interfaces, approved configuration and final functional acceptance record before service release.

Bently Nevada 3500/32M 125720-02 Manuals & Downloads
Bently Nevada 3500/32M 125720-02 Technical Reference (PDF)Bently Nevada 3500/32M 125720-02 Official Datasheet (PDF)

Important Notice: The first document is an exact-model technical reference. The second is the unmodified official manufacturer family datasheet used for installation limits and technical evidence.

Alarm annunciation
Drive a documented annunciator or interface from independent rack alarm logic.
Protection interlock
Combine approved Alert, Danger and channel-status states in a programmed relay expression.
Equipment permissive
Use relay voting to provide an engineered machine permissive within the stated contact envelope.
Shutdown interface
Transfer a verified protection decision to the plant shutdown circuit through documented isolation.
Read the applicable Bently Nevada installation instructions before work. Verify 3500/32M 125720-02, its installed system arrangement and configured interfaces before commissioning.
1
Verify whether the exact spare is a control module or an output module before replacement.
2
Confirm the installed system uses standard or safety/hazardous relay ratings before connecting the load.
3
De-energize the external relay circuit and verify isolation before removing either front or rear module.
4
Restore each output's normally energized or de-energized programming from the approved configuration.
5
Check AND/OR voting logic against the cause-and-effect record rather than copying neighboring channels.
6
Keep switching voltage, current and VA inside the published envelope, including inrush conditions.
7
Prove each relay using a controlled input state and observe both rack indication and external circuit response.
8
Record final relay state, logic expression, contact path and alarm/shutdown acceptance result.

Technical notes

Technical notes

Verify whether the exact spare is a control module or an output module before replacement. Record final relay state, logic expression, contact path and alarm/shutdown acceptance result.

FAQS

  • Why is 3500/32M 125720-02 reserved for hazardous-area and functional-safety relay service?
    125720-02 is the documented output module variant for those systems, so its identity and restricted contact envelope must be preserved.
  • What reduced voltage boundary applies to circuits switched by 3500/32M 125720-02?
    For the safety/hazardous configuration, keep the switched circuit at or below 30 Vac/Vdc and 2 A.
  • How should normally energized logic be restored around 3500/32M 125720-02?
    Recover the approved relay logic and fail-state strategy from the safety or hazardous-area configuration; do not infer it from present contact state.
  • Which rack conditions may command the output paired with 3500/32M 125720-02?
    The 3500/32M logic can combine Alert, Danger, Not-OK and Programmable Logic states using AND/OR expressions.
  • What does the 250 Vrms suppressor specification imply for 3500/32M 125720-02?
    It identifies the installed arc-suppression component; external circuit design must still comply with the lower safety/hazardous contact rating.
  • How is the 5.8 W module load relevant when replacing 3500/32M 125720-02?
    Confirm the completed relay assembly and rack power budget remain consistent with the documented 5.8 W typical consumption.
  • What inspection should precede insertion of 3500/32M 125720-02?
    Inspect the rear connector, field wiring, channel labels and safety/hazardous circuit isolation before seating the output module.
  • Which acceptance evidence is needed for 3500/32M 125720-02 in a safety-related circuit?
    Retain the exact spare identity, programmed logic, de-energized test state, external circuit response and authorized proof-test result.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.