DSAI145 57120001-HA

ABB DSAI145 control-system module product reference
In Stock
Ships by Wednesday, September 9
Fast Shipping Available

Product Describe:

ABB DSAI145 is listed under product code EXC57120001-HA and part number 57120001-HA. Confirm the installed rack, terminal unit and cable before replacement.

Ask our team:

Get a quick price for: DSAI145 57120001-HA
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for DSAI145 57120001-HA

Technical specifications for DSAI145 57120001-HA

  • Manufacturer:
    ABB
  • Product Category:
    DCS System
  • Spare Part Number:
    DSAI145 57120001-HA
  • Estimated shipping dimensions:
    2x24.8x24.3cm
  • Weight:
    0.45 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Sweden
  • Model:
    DSAI145
  • Part number:
    57120001-HA
  • ABB product code:
    EXC57120001-HA

Information

Information

Overview Manuals Common Applications Product Precautions
ABB DSAI145 is listed by ABB under product code EXC57120001-HA and part number 57120001-HA.
  • Model: DSAI145
  • Part number: 57120001-HA
  • ABB product code: EXC57120001-HA
  • Manufacturer: ABB

Match the complete physical nameplate, installed rack, terminal unit, cable, connector and project documentation before replacement. Isolate the equipment, record wiring and back up the applicable configuration before work; complete documented channel, diagnostic and alarm checks afterward.

Important Notice: Use the approved ABB and site procedures for installation, testing and return to service.

Apter Power DSAI145 57120001-HA Manuals and Guides

Important Notice: Both documents are specific to ABB DSAI145. Confirm the complete module label and installed-system requirements before installation or replacement.

Installed-base maintenance
Supports planned maintenance of ABB control-system installations using DSAI145.
Module replacement
Supports like-for-like replacement after the complete model, part number, rack and terminal hardware are matched.
Wiring verification
Supports checking field wiring, terminals, cable assignments and project drawings before commissioning.
Commissioning and troubleshooting
Supports documented channel, diagnostic, alarm and configured-response checks after service work.
Read the applicable ABB and installed-system instructions before work. Verify the complete DSAI145 label and system configuration.
1
Match the complete DSAI145 label, 57120001-HA part number and EXC57120001-HA ABB product code before use.
2
Confirm the exact host controller, rack position, terminal unit, cable, connector and project revision.
3
De-energize the equipment and follow the site's approved electrical and process-safety procedure before disturbing hardware or wiring.
4
Back up the applicable controller and I/O configuration before replacement or migration work.
5
Compare every conductor, shield, polarity and terminal number with approved drawings before moving wiring.
6
Do not transfer electrical or mechanical data from a related DSAI model or a different part-number suffix.
7
Perform documented power, channel, diagnostic, alarm and configured fail-state checks after installation.
8
Record the installed module label, rack position and test results in the maintenance history.

Alternative Names

Alternative Names

57120001-HA EXC57120001-HA

Technical notes

Technical notes

ABB product identity: DSAI145, 57120001-HA, EXC57120001-HA. Confirm the installed rack, terminal unit, cable and connector from the project documentation. Complete controlled post-installation checks before return to service.

FAQS

  • Is ABB DSAI145 compatible with my installed controller or rack?
    Match the complete module label, rack family, slot, terminal unit, cable, connector and project documentation before installation.
  • What information should I provide with an RFQ?
    Provide clear photos of the complete nameplate, front and rear connectors, installed rack and slot, terminal unit, cable code and project drawing reference.
  • Can DSAI145 replace another DSAI model?
    Do not treat a related DSAI model as a direct replacement. Confirm the exact ABB replacement path and the installed project's hardware and signal requirements.
  • What should be checked before installation?
    Verify isolation, rack position, keying, terminal unit, cable, connector, channel assignment and the current configuration backup.
  • Can DSAI145 be removed while the system is energized?
    Follow the exact ABB hardware instructions and the site's approved procedure. De-energize the affected equipment unless the installed-system documentation explicitly permits another method.
  • How should field wiring be verified?
    Compare each conductor, shield, polarity and terminal number with the approved drawings before moving wiring from the existing module.
  • Which commissioning tests are required after replacement?
    Complete documented power, channel, diagnostic, alarm, interlock and configured fail-state checks before return to service.
  • What should be checked if a channel does not respond?
    Check the terminal assignment, cable continuity, polarity, field signal, rack power, configuration, diagnostics and channel mapping in a controlled sequence.
  • How should configuration be backed up?
    Save the current controller and I/O configuration with its project revision, then verify that the backup can be identified and restored before work begins.
  • How should a spare DSAI145 be stored?
    Record the complete label and inspection status, retain protective packaging, and follow the site's ESD, humidity and temperature controls.
  • What troubleshooting information should be recorded?
    Record diagnostics, channel conditions, alarms, wiring checks, power measurements, configuration revision and the sequence that produced the fault.
  • What must be confirmed before returning the system to service?
    Confirm wiring, configuration, channel response, diagnostics, alarms, interlocks and the approved commissioning record.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.