Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
HIMA F7133
HIMA F7133
HIMA F7133
HIMA F7133
HIMA F7133
HIMA F7133
Product image is representative; revision or series may vary. Contact us to request a specific version.

F7133

4-Channel Power Distribution Module with Fuse Monitoring
In Stock
Ships by Wednesday, October 14
Fast Shipping Available

Product Describe:

HIMA F7133 distributes four protected 24 V supply paths and an L- return in the documented HIMA system. Its original data sheet specifies four miniature fuses with individual LED monitoring and a common fuse-status relay.

Ask our team:

Get a quick price for: F7133
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for F7133

Technical specifications for F7133

  • Manufacturer:
    HIMA
  • Product Category:
    PLC Systems
  • Spare Part Number:
    F7133
  • Estimated shipping dimensions:
    20.7x14.7x6.7cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Protected supply paths:
    4
  • Supply arrangement:
    24 V DC and L- return
  • Fuse rating:
    Maximum 4 A slow-blow
  • Relay switching:
    Approximately 100 ms
  • Relay contact load:
    30 V / 4 A continuous
  • Fuse-tripped residual voltage:
    0 V
  • Fuse-tripped residual current:
    0 mA
  • Space requirement:
    4 TE
  • 24 V DC draw:
    60 mA

Information

Information

Overview Manuals Common Applications Product Precautions
HIMA F7133 distributes four protected 24 V supply paths and an L- return in the documented HIMA system. Its original data sheet specifies four miniature fuses with individual LED monitoring and a common fuse-status relay.
  • Four protected 24 V supply paths feed the documented HIMA I/O arrangement.
  • Each miniature fuse has its own LED condition indication.
  • The L- return is distributed through the specified front connections.
  • The d22/z24 status contact is closed only when all four fuses are in order.

Use the module in the approved HIMA rack and cabinet power-distribution design.

Important Notice: Confirm the actual supply, fuse and wiring state before interpreting a flashing LED or relay state.

HIMA F7133 Manuals & Downloads
HIMA F7133 Technical Reference (PDF)HIMA F7133 Installation & Commissioning Guide (PDF)

The first PDF presents the F7133 distribution, fuse and relay values; the second is a separate installation and acceptance checklist. Both use the original HIMA F 7133 (9912) data sheets as their technical basis.

I/O slot supply
Feed four documented rear 24 V paths to assigned HIMA I/O slots.
Sensor contact supply
Use the front distribution pins in the approved field circuit.
Fuse diagnostics
Read each LED in the context of fuse and supply condition.
Common status relay
Use d22/z24 in the controlled fuse-status monitoring path.
For HIMA F7133, check the four distribution paths, fuse condition and status contacts against the actual cabinet wiring.
1
Record the complete F7133 marking and installed slot.
2
Use the approved power-isolation procedure before working on the module.
3
Confirm each miniature fuse is no more than 4 A slow-blow.
4
Trace rear d6, d10, d14 and d18 supply destinations.
5
Verify front pins 1-4 and the L- return.
6
Distinguish a missing 24 V supply from a faulty fuse.
7
Compare each LED on/off/flashing state with the HIMA table.
8
Test d22/z24 contact response before controlled release.

Technical notes

Technical notes

Verify the complete F7133 marking, four fuse ratings (maximum 4 A slow-blow), rear d6/d10/d14/d18 path assignments, front 1-4 and L- connections, LED states and d22/z24 relay response against the actual cabinet drawing.

FAQS

  • What is HIMA F7133?
    It is a four-path 24 V power distribution module with individual fuse monitoring.
  • How are fuse conditions indicated?
    Each miniature fuse has a related LED; the original HIMA table distinguishes healthy, missing-supply and faulty-fuse states.
  • What fuse rating is documented?
    The manufacturer specifies a maximum 4 A slow-blow fuse.
  • When is the status relay closed?
    The d22/z24 relay contact is closed when all four fuses are in order and de-energizes otherwise.
  • Which connections must be checked?
    Verify rear d6/d10/d14/d18 outputs, front pins 1-4 and L-, and the installed cabinet wiring.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.