Product Describe:

Bently Nevada 350500-00-00-00-11-00 is the documented 350500 Dynamic Pressure Charge Amplifier for the Bently Nevada 350500 dynamic pressure measurement system. It converts a compatible dynamic-pressure sensor charge signal into a conditioned voltage output.

Ask our team:

Get a quick price for: 350500-00-00-00-11-00
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 350500-00-00-00-11-00

Technical specifications for 350500-00-00-00-11-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    350500-00-00-00-11-00
  • Estimated shipping dimensions:
    2.5x25.8x24cm
  • Weight:
    0.85 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Sensitivity:
    100 mV/psi +/-2% at 150 Hz
  • Dynamic range:
    +/-50 psi peak
  • Output resistance:
    50 ohm
  • Supply:
    -19.6 to -26 V DC without barriers
  • Maximum current:
    14.68 mA no load
  • Mounting:
    Panel or DIN rail

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 350500-00-00-00-11-00 converts a compatible dynamic-pressure sensor charge signal into a conditioned voltage output.
  • Conditions dynamic-pressure charge signals
  • Provides a documented 100 mV/psi output
  • Supports panel or DIN-rail mounting
  • Interfaces the sensor with monitoring electronics

The article is installed only with the documented Bently Nevada 350500 dynamic pressure measurement system components. Commissioning preserves the exact suffix identity, physical interfaces, wiring, shielding, configuration and controlled response evidence.

Important Notice: Confirm Bently Nevada 350500-00-00-00-11-00, complete article suffix, installed host, mating components, mounting, connectors, cable route, wiring, shielding, grounding, monitor configuration and controlled functional-test results before commissioning.

Apter Power Bently Nevada 350500-00-00-00-11-00 Manuals and Guides

The first document presents model-specific technical and system data. The second provides a distinct installation, connection, commissioning and acceptance workflow.

Combustion dynamic-pressure monitoring
Conditions a compatible pressure-sensor signal for monitoring.
Gas-turbine pressure diagnostics
Provides conditioned dynamic-pressure output for diagnostic analysis.
Compressor pulsation monitoring
Interfaces a charge-output sensor with the monitoring channel.
Charge-amplifier replacement
Restores a documented panel or DIN-rail signal-conditioning position.
Read the applicable Bently Nevada installation instructions before work. Verify 350500-00-00-00-11-00, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm Bently Nevada 350500-00-00-00-11-00 and the complete installed article marking.
2
Place the monitored machine and protection channel in the approved maintenance state.
3
Isolate the affected circuit and apply ESD-safe handling.
4
Record the installed position, connectors, cable route, shielding and 350500 mounting and approval execution before removal.
5
Confirm the documented host, mating components and physical interfaces.
6
Restore the approved mounting, wiring, shielding and monitor configuration.
7
Review supply, bias, channel and monitor diagnostics after energization.
8
Complete a controlled response and alarm test before service release.

Alternative Names

Alternative Names

350500 mounting and approval execution

Technical notes

Technical notes

Match Bently Nevada 350500-00-00-00-11-00 to the documented host and mating interfaces, and record the as-found 350500 mounting and approval execution, connections, cable route, shielding and configuration. Restore the approved arrangement and verify diagnostics and controlled channel response before release.

FAQS

  • How should amplifier identity be verified for Bently Nevada 350500-00-00-00-11-00?
    Confirm Bently Nevada 350500-00-00-00-11-00, complete article suffix, installed host, mating components, mounting, connectors, cable route, wiring, shielding, grounding, monitor configuration and controlled functional-test results before commissioning.
  • Which record controls charge-input wiring on Bently Nevada 350500-00-00-00-11-00?
    Match Bently Nevada 350500-00-00-00-11-00 to the documented host and mating interfaces, and record the as-found 350500 mounting and approval execution, connections, cable route, shielding and configuration. Restore the approved arrangement and verify diagnostics and controlled channel response before release.
  • What must be preserved for negative supply when servicing Bently Nevada 350500-00-00-00-11-00?
    Record the installed position, connectors, cable route, shielding and 350500 mounting and approval execution before removal.
  • How is 100 mV/psi output isolated before work on Bently Nevada 350500-00-00-00-11-00?
    Place the monitored machine and protection channel in the approved maintenance state. Isolate the affected circuit and apply ESD-safe handling.
  • What official check applies to DIN/panel mounting for Bently Nevada 350500-00-00-00-11-00?
    Confirm the documented host, mating components and physical interfaces.
  • How is shielding restored after fitting Bently Nevada 350500-00-00-00-11-00?
    Restore the approved mounting, wiring, shielding and monitor configuration.
  • Which diagnostic confirms dynamic-pressure test for Bently Nevada 350500-00-00-00-11-00?
    Review supply, bias, channel and monitor diagnostics after energization.
  • What proves acceptance evidence is accepted for Bently Nevada 350500-00-00-00-11-00?
    Complete a controlled response and alarm test before service release.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire