125768-01

RIM I/O Module with RS232/RS422 Interface
In Stock
Ships by Sunday, September 13
Fast Shipping Available

Product Describe:

Bently Nevada 125768-01 is a RIM I/O Module with RS232/RS422 Interface. It connects host software to the rack for configuration and machinery-data retrieval.

Ask our team:

Get a quick price for: 125768-01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 125768-01

Technical specifications for 125768-01

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    125768-01
  • Estimated shipping dimensions:
    2.5x11.2x24.2cm
  • Weight:
    0.45 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Serial interfaces:
    RS232; RS422; external modem
  • Protocol:
    Bently Nevada proprietary
  • Maximum serial data rate:
    38.4 kbaud
  • RS232 maximum cable length:
    30 m
  • RS422 maximum cable length:
    1200 m
  • External modem cable length:
    3 m typical
  • Rack connector interface:
    RS422
  • Rack connector data rate:
    38.4 kbaud maximum
  • Rack addresses:
    63 selectable
  • System-contact current:
    Less than 1 mA dc
  • OK relay rating:
    5 A at 24 Vdc or 120 Vac
  • Operating temperature:
    -30 to +65 degC
  • Storage temperature:
    -40 to +85 degC
  • Humidity:
    95% non-condensing
  • Rear rack space:
    1 full-height slot

Information

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 125768-01 is the RS232/RS422 rear I/O module for a 3500/20 Rack Interface Module. It connects host software to the rack for configuration and machinery-data retrieval.
  • Provides selectable RS232 or RS422 host communication for the 3500/20 RIM
  • Carries proprietary rack configuration and data-retrieval traffic
  • Supports long-distance RS422 and short-distance RS232 or modem connections
  • Exposes Trip Multiply, Alarm Inhibit, Rack Reset and rack-OK interfaces

125768-01 installs with 3500 rack rear slot, 3500/20 standard or TMR RIM, Host computer or external modem, RS232 or RS422 communication cable in an engineered 3500/20 Rack Interface System configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this rim i/o module with rs232/rs422 interface.

Important Notice: Confirm the complete 125768-01 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 125768-01 Manuals and Guides
Apter Power 125768-01 Product Technical Reference PDFBently Nevada 125768-01 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Local rack configurationProvides selectable RS232 or RS422 host communication for the 3500/20 RIM
Long-distance RS422 host linkCarries proprietary rack configuration and data-retrieval traffic
Multi-rack communications chainSupports long-distance RS422 and short-distance RS232 or modem connections
External modem service connectionExposes Trip Multiply, Alarm Inhibit, Rack Reset and rack-OK interfaces
Read the applicable Bently Nevada installation instructions before work. Verify 125768-01 and the installed 3500/20 Rack Interface System configuration.
1Verify 125768-01 and its paired 3500/20 RIM before changing any serial connection.
2Place the configuration keylock in the approved state before service work.
3Record the interface selection, rack address and host cable destination.
4Maintain RS232 and RS422 cable lengths within their published limits.
5Use the rack connector only for the documented RS422 daisy-chain path.
6Isolate Trip Multiply, Alarm Inhibit and Rack Reset contacts before rewiring.
7Confirm OK relay behavior and CONFIG OK indication after module insertion.
8Test rack configuration and data retrieval from the actual host workstation.

Technical notes

Technical notes

Set the interface selector to the installed physical layer, verify rack address uniqueness and confirm host communication at the documented rate before enabling remote configuration access.

FAQS

  • How can 125768-01 be commissioned for local rack configuration?
    Apply a controlled input or command, review the model-specific diagnostics and prove the expected measurement, indication and protection response before releasing the channel.
  • What technical value deserves special attention when checking 125768-01?
    Verify the published rs422 maximum cable length value of 1200 m against the installed configuration and test record.
  • Can 125768-01 be exchanged with another 3500 I/O or monitor execution?
    Only when the complete part number, termination style, transducer or interface type and approved rack configuration match the installed duty; do not transfer settings from an adjacent model.
  • What evidence should be retained after 125768-01 returns to service?
    Retain the full 125768-01 identity, as-left connections, restored configuration, final diagnostics and the controlled functional-test result for long-distance rs422 host link.
  • Which rack hardware must be matched before installing 125768-01?
    Match 125768-01 to the documented 3500 rack rear slot and 3500/20 standard or TMR RIM; confirm the front/rear slot pairing and the complete physical marking before connection.
  • What as-found information should an engineer record before removing 125768-01?
    Record every channel or port assignment, connector identity, configured function, cable tag and diagnostic state associated with 125768-01.
  • How should 125768-01 be isolated before field wiring is disturbed?
    Place the protected machine in its approved maintenance state, isolate rack and field energy applicable to Host computer or external modem, and prove the terminals safe before disconnection.
  • Which configuration should be restored after replacing 125768-01?
    Restore the approved 3500/20 Rack Interface System slot, channel or interface configuration and verify that every connected circuit retains its original assignment.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.