Speak to a sourcing specialist
sales13@apterpower.com

NINT-42 58907952H

MAIN CIRCUIT INTERFACE BOARD
ABB NINT-42 58907952H
ABB NINT-42 58907952H
ABB NINT-42 58907952H
ABB NINT-42 58907952H
ABB NINT-42 58907952H
ABB NINT-42 58907952H
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

MAIN CIRCUIT INTERFACE BOARD 

NINT-42C is Coated Version

Integrated handling of analog

digital, and high-speed serial 

fiber-optic communications

Get a quick price for NINT-42 58907952H
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for NINT-42 58907952H

  • Manufacturer:
    ABB
  • Product Category:
    DCS Systems
  • Spare Part Number:
    NINT-42 58907952H
  • Estimated shipping dimensions:
    36.5x15.4x2cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    SWEDEN
  • Input Supply Voltage:
    +24V DC, +5V DC, ±15V DC
  • Protection Class:
    IP00
  • Operating Ambient Temperature:
    0°C to +50°C
  • Storage Temperature Range:
    -40°C to +70°C
  • Relative Humidity:
    5% to 95%

Information

Overview Manuals Common Applications Product Precautions
The NINT-42 58907952H is a main circuit interface board manufactured by ABB, a global automation giant. It plays a crucial role as a communication and signal bridge in industrial drive systems.
    • Precise High-Speed IGBT Gate Driving
    • Zero-Latency Bus Monitoring & Hardware Protection
    • EMI-Immune High-Speed Fiber Optic Communication
Acting as an essential physical link between the low-voltage control unit and the high-voltage power stage, this board takes full responsibility for real-time signal conversion and hardware protection. It converts incoming low-voltage control commands into pulse drive signals for high-power IGBT modules, while instantly feeding back operational status and critical safety metrics—such as overcurrent and overtemperature—to the main control system.Although officially classified as an obsolete legacy spare part by the OEM, the NINT-42 remains a mission-critical asset for heavy industries worldwide—including metallurgy, pulp & paper, chemical processing, mining, and port machinery—to eliminate costly unscheduled downtime. We handle enquiries for new, unused NINT-42 modules. Share the complete part reference and required quantity so availability and supply details can be checked before a quotation is issued.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 ABB NINT-42 58907952H MAIN CIRCUIT INTERFACE BOARD Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Metallurgy & Steel
Used to control high-power motors for blast furnace hoists, blast furnace blowers, and steel ingot rolling mills, ensuring heavy-duty speed regulation during metal rolling processes.

Pulp & Paper
Applied in the sectional multi-motor synchronous control of large paper machine drive chains to maintain constant paper tension during high-speed forming processes.

Oil & Gas
Controls main crude oil pumps, natural gas compressors, and drilling rig winches for long-distance pipelines on offshore drilling platforms or onshore oilfields.

Thermal Power
Controls the speed regulation of boiler primary fans, induced draft fans, boiler feedwater pumps, and circulating water pumps, achieving energy-saving operation in power plant fan systems.

Chemical & Petrochemical Industry
Controls high-pressure reactor agitators, ammonia compressors in large fertilizer plants, and long-distance transit pumps for various toxic or flammable media.

 When using or replacing the NINT-42 (58907952H) interface board, the most critical steps are safe discharging and hardware pad pairing. The drive cabinet must only be opened after being powered off for 5 to 10 minutes and with the DC bus voltage verified at 0V. Since it is a universal driver board, you must manually duplicate the short-circuit solder pad configuration from the old board to the new one prior to installation to match the specific drive's power rating and frame size. Furthermore, due to its IP00 open-board classification, technicians must wear anti-static wrist straps, ensure fiber optic connections are clean, and maintain proper cable bending radiuses. Blind "plug-and-play" is strictly prohibited, as it can cause immediate communication faults or lead to catastrophic IGBT explosions under load.

FAQ View All FAQ

  • What is NINT-42 58907952H?
    It is the core Main Circuit Interface Board for ABB ACS600 series high-power drives serviced in the late 1990s and early 2000s, responsible for signal conversion between power stage driving and low-voltage control circuits.
  • What is the primary purpose of NINT-42 58907952H?
    Its primary purpose is to receive commands from upper control boards and convert them into IGBT gate trigger pulses, while safely feeding back state signals like DC bus voltage, overcurrent, and overtemperature from the high-power inverter to the control system.
  • How to properly use a hardware device like NINT-42 58907952H?
    It cannot be used independently. It must be embedded into a compatible ABB drive power module, connected to the power supply board via ribbon cables, and to the main control board via fiber optics after the drive is powered off and the DC bus is completely discharged, then secured onto its dedicated mounting bracket.
  • What are the anti-static requirements when installing NINT-42 58907952H?
    Due to a large number of sensitive onboard CMOS SMD chips, field technicians must wear an anti-static wrist strap (with a grounding wire) or touch a metallic grounded body beforehand to discharge, and should only handle the board by its edges, strictly avoiding direct touch to gold fingers and chips.
  • Facing the obsolescence of NINT-42 58907952H, what is the long-term industrial automation maintenance recommendation?
    As spare parts become increasingly scarce and severely aged, the best long-term solution is to gradually plan a modernization retrofit or total upgrade of the entire ACS600 drive, migrating t
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.